Analysis of a retrieved delta III total shoulder prosthesis.
نویسندگان
چکیده
A reversed Delta III total shoulder prosthesis was retrieved post-mortem, eight months after implantation. A significant notch was evident at the inferior pole of the scapular neck which extended beyond the inferior fixation screw. This bone loss was associated with a corresponding, erosive defect of the polyethylene cup. Histological examination revealed a chronic foreign-body reaction in the joint capsule. There were, however, no histological signs of loosening of the glenoid base plate and the stability of the prosthetic articulation was only slightly reduced by the eroded rim of the cup.
منابع مشابه
Revision of shoulder replacement with a reversed shoulder prosthesis (Delta III): report of five cases.
The authors report on their experience in revision total shoulder arthroplasty using the Delta III shoulder prosthesis, a reversed constrained prosthesis which is known to give good functional results in the rotator cuff-deficient shoulder. It was implanted in patients with a failed total or hemishoulder prosthesis. The Constant-Murley score was used to assess the functional outcome. The prelim...
متن کاملReverse shoulder arthroplasty: does reduced medialisation improve radiological and clinical results?
The purpose of this retrospective study was to assess the effect of the reduced medialisation of the Arrow reverse shoulder prosthesis on short-term clinical and radiological results. The clinical and radiological results of 47 Delta III reverse prostheses and 49 Arrow reverse prostheses were retrospectively compared at a minimum of twelve months follow-up. There was a significant increase (p <...
متن کاملSix-year experience with the Delta III reverse shoulder prosthesis.
PURPOSE To report the clinical and radiographic results and complications of the Delta III reverse prosthesis. METHODS 24 women and 2 men aged 62 to 84 (mean, 75) years underwent total shoulder replacement using the Delta III reverse prosthesis. Patient diagnoses were massive rotator cuff tear (n=20), disabling sequelae of proximal humeral fractures (n=3), and failure of an unconstrained arth...
متن کاملComparison of bone removed with reverse total shoulder arthroplasty.
INTRODUCTION A computer model quantified glenoid base - plate surface contact area and the amount of humeral and glenoid bone removed by three different reverse shoulder prosthesis designs when implanted with various techniques. METHODS The computer model quantified differences in glenoid baseplate contact area and the cortical and cancellous humeral and glenoid bone removed to implant the 36...
متن کاملThe Midterm Results of the Delta Xtend Reverse Shoulder System: A Five-Year Outcome Study
Background: The purpose of this study was to examine the mid-term functional outcomes, radiographic results,and revision rates of patients treated with the Delta Xtend Reverse Shoulder System for both primary and revisionarthroplasty indications.Methods: A retrospective review was conducted of records for all individuals who underwent a reverse shoulderarthroplasty using the Delta Xtend Reverse...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 86 8 شماره
صفحات -
تاریخ انتشار 2004