Performance of the COBAS AMPLICOR HCV MONITOR test, version 2.0, an automated reverse transcription-PCR quantitative system for hepatitis C virus load determination.

نویسندگان

  • G Gerken
  • T Rothaar
  • M G Rumi
  • R Soffredini
  • M Trippler
  • M J Blunk
  • A Butcher
  • S Soviero
  • G Colucci
چکیده

A clinical evaluation of an automated quantitative PCR assay, the COBAS AMPLICOR HCV MONITOR test, version 2.0 (v2.0), was carried out to assess the performance of this test in comparison with that of the previous, manual version, the AMPLICOR HCV MONITOR test, and with that of nested PCR. Serial dilutions of serum samples infected with genotype 1b, 2a, or 3, as well as synthetic RNA transcripts and serum samples derived from 87 patients with chronic hepatitis C and infected with genotype 1a, 1b, 2a, 2b, 3a, 3b, 4, or 5, were analyzed to determine the ability of the system to efficiently quantify various hepatitis C virus (HCV) genotypes. These experiments showed that the COBAS AMPLICOR HCV MONITOR test, v2.0, has mean intra-assay, interassay, and interoperator coefficients of variation that range from 22 to 34.5% and a 3-logarithm dynamic range, which spans from 10(3) to 10(6) copies/ml. Compared to the previous, manual version of the test, the COBAS AMPLICOR HCV MONITOR test, v2.0, showed an improved efficacy for all genotypes, especially genotypes 2, 3, and 4, whose estimated concentrations were on average 1 logarithm higher. When used to monitor patients under treatment, however, both versions showed the same patterns of viremia, indicating that the COBAS AMPLICOR HCV MONITOR test, v2.0, and the AMPLICOR HCV MONITOR test were equally effective at detecting relative viremia changes in serial samples. As expected, the automated test was less sensitive than nested PCR; among specimens from a cohort of patients treated with interferon, nested PCR identified three more viremic specimens, which probably contained very low concentrations of HCV RNA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical evaluation of the automated COBAS AMPLICOR HCV MONITOR test version 2.0 for quantifying serum hepatitis C virus RNA and comparison to the quantiplex HCV version 2.0 test.

A second-generation hepatitis C virus (HCV) quantitative assay (COBAS AMPLICOR HCV MONITOR Test, version 2.0; COBAS HCM-2) has been developed, with the intention of achieving equivalent quantification of all HCV genotypes and improving assay performance. To evaluate the clinical performance of COBAS HCM-2 and its utility in predicting the response to alpha interferon treatment, sera from 215 ch...

متن کامل

Assessment of viral loads in patients with chronic hepatitis C with AMPLICOR HCV MONITOR version 1.0, COBAS HCV MONITOR version 2.0, and QUANTIPLEX HCV RNA version 2.0 assays.

The correlation between response to antiviral therapy and pretreatment viral load in patients with chronic hepatitis C has prompted the development of quantitative assays to measure viral load. The aim of our study was to assess the clinical relevance of the newly developed semiautomated PCR system COBAS HCV MONITOR version 2.0 in comparison with (i) the AMPLICOR HCV MONITOR version 1.0 assay, ...

متن کامل

Comparison of qualitative (COBAS AMPLICOR HCV 2.0 versus VERSANT HCV RNA) and quantitative (COBAS AMPLICOR HCV monitor 2.0 versus VERSANT HCV RNA 3.0) assays for hepatitis C virus (HCV) RNA detection and quantification: impact on diagnosis and treatment of HCV infections.

Quantitative measurements of serum hepatitis C virus (HCV) RNA are becoming increasingly important in the management of HCV-infected patients. Here we compared two quantitative assays, the COBAS AMPLICOR HCV Monitor 2.0 assay (Roche Diagnostics) and the branched DNA-based VERSANT HCV RNA 3.0 assay (Bayer Diagnostics) for HCV RNA measurement in 344 samples derived from 120 patients with chronic ...

متن کامل

Evaluation of the invader assay for genotyping hepatitis C virus.

The Invader 1.0 assay (Invader HCV Genotyping Assay, version 1.0; Third Wave Technologies, Inc., Madison, WI) has been developed for the rapid differentiation of hepatitis C virus (HCV) genotypes 1 to 6 based on sequence variation within the HCV 5' noncoding (NC) region. In the present study, we evaluated the compatibility of Invader 1.0 with the COBAS MONITOR (COBAS AMPLICOR HCV MONITOR Test, ...

متن کامل

Evaluation of the automated COBAS AMPLICOR hepatitis C virus PCR system.

To evaluate the reliability and feasibility of the automated Roche COBAS AMPLICOR PCR system for routine detection of hepatitis C virus (HCV) RNA, a total of 405 serum samples previously tested by an in-house nested PCR and manual Roche AMPLICOR microwell plate HCV test were examined. Complete concordance was found between the results with the HCV COBAS AMPLICOR system and the previously determ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 38 6  شماره 

صفحات  -

تاریخ انتشار 2000