The impact of a preloaded intraocular lens delivery system on operating room efficiency in routine cataract surgery
نویسندگان
چکیده
PURPOSE The aim of this study was to evaluate the operational impact of using preloaded intraocular lens (IOL) delivery systems compared with manually loaded IOL delivery processes during routine cataract surgeries. METHODS Time and motion data, staff and surgery schedules, and cost accounting reports were collected across three sites located in the US, France, and Canada. Time and motion data were collected for manually loaded IOL processes and preloaded IOL delivery systems over four surgery days. Staff and surgery schedules and cost accounting reports were collected during the 2 months prior and after introduction of the preloaded IOL delivery system. RESULTS The study included a total of 154 routine cataract surgeries across all three sites. Of these, 77 surgeries were performed using a preloaded IOL delivery system, and the remaining 77 surgeries were performed using a manual IOL delivery process. Across all three sites, use of the preloaded IOL delivery system significantly decreased mean total case time by 6.2%-12.0% (P<0.001 for data from Canada and the US and P<0.05 for data from France). Use of the preloaded delivery system also decreased surgeon lens time, surgeon delays, and eliminated lens touches during IOL preparation. CONCLUSION Compared to a manual IOL delivery process, use of a preloaded IOL delivery system for cataract surgery reduced total case time, total surgeon lens time, surgeon delays, and eliminated IOL touches. The time savings provided by the preloaded IOL delivery system provide an opportunity for sites to improve routine cataract surgery throughput without impacting surgeon or staff capacity.
منابع مشابه
Treatment of ophidism-induced bilateral canine cataract by extracapsular lens extraction and intraocular lens implantation
The aim of this study was to report a new cause of cataract, namely snake bite induced cataract in a dog. A 3-year-old male mongrel dog was referred to our clinic for the assessment of cataract in both eyes. The dog was bitten by a snake nearly 4 months ago. A 40 dioptre acrylic lens with 13 mm haptics was implanted into the lens capsule. In the left eye, posterior synechia was detected in the ...
متن کاملPreloaded and non-preloaded intraocular lens delivery system and characteristics: human and porcine eyes trial.
AIM To compare characteristics of preloaded and non-preloaded intraocular lens (IOL) delivery systems during IOL delivery procedures. METHODS Total 101 human eyes were included in this prospective observational case series. Delivery characteristics of 5 types of IOLs including iSert250 NC60 (NC60), EnVista MX60 (MX60), AcrySof IQ SN60WF (SN60WF), TECNIS ZCB00 (ZCB00), and TECNIS PCB00 (PCB00)...
متن کاملمقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کاملکاربرد لنزهای داخل چشمی در جراحی کاتاراکت و عوامل تأثیرگذار بر دید بیمار
Introduction: With the growing and rapid development of refractive surgery, researches focus increasingly on improvement of visual quality after cataract surgery. Intraocular lenses (IOLs) were a successful effort in the field of cataract surgery. Despite significant advances in cataract surgery, several complications related to surgical technique and IOL design after surgery can cause vision c...
متن کاملResident surgeon efficiency in femtosecond laser-assisted cataract surgery
PURPOSE Comparison of resident surgeon performance efficiencies in femtosecond laser-assisted cataract surgery (FLACS) versus conventional phacoemulsification. PATIENTS AND METHODS A retrospective cohort study was conducted on consecutive patients undergoing phacoemulsification cataract surgery performed by senior ophthalmology residents under the supervision of 1 attending physician during a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -