Time-dependent mechanical properties of HA/TCP particles in relation to morsellized bone grafts for use in impaction grafting.
نویسندگان
چکیده
In reconstructive surgery human bone defects are sometimes filled with the use of the impaction bone grafting technique. Currently different types of biomaterial particles are being developed as bone-substitute materials. Before these biomaterials can be applied their mechanical and biological behavior should be characterized. In this study the time-dependent mechanical behavior of biomaterial particles with different tri-calcium-phosphate/hydroxy-apatite (TCP:HA) ratios, particle sizes, and porosities is determined and compared to the behavior of human bone grafts, the latter being the standard material currently used to augment bone defects. The mechanical properties were assessed with the use of dynamic confined compression creep tests with a loading and unloading phase. Different graft material groups were tested, consisting of 100% human bone grafts, 100% biomaterial particles, and 50:50 weight mixtures of human grafts and biomaterial particles. No damage to the particles was observed by the impaction in the test chamber or by the dynamic load. Relative to the human graft material, the biomaterial particles hardly deformed under loading, were much stiffer, and showed almost no viscoelastic behavior. The mixtures showed intermediate results. Particle size and porosity influenced the behavior of the biomaterial particles. TCP:HA ratio did not have a great effect. The conclusion is that the application of these particles should be done with great care, as their mechanical behavior is drastically different than that of the human graft material. Mixing it with human bone grafts gave the material some biphasic, viscoelastic behavior that may be important for its biological response.
منابع مشابه
Tricalcium-phosphate and hydroxyapatite bone-graft extender for use in impaction grafting revision surgery. An in vitro study on human femora.
Impacted morsellised allografts have been used successfully to address the problem of poor bone stock in revision surgery. However, there are concerns about the transmission of pathogens, the high cost and the shortage of supply of donor bone. Bone-graft extenders, such as tricalcium phosphate (TCP) and hydroxyapatite (HA), have been developed to minimise the use of donor bone. In a human cadav...
متن کاملFilling of segmental bone defects in revision knee arthroplasty using morsellized bone grafts contained within a metal mesh.
For revision knee surgery with uncontained tibial bone defects, the authors report the containment of compacted morsellized allograft using metal-wire mesh, followed by implantation of a cemented total knee prosthesis. This method is comparable to the "impaction grafting technique" described for revision hip surgery and could be an alternative to metal wedges, augmented components, custom-made ...
متن کاملImpaction grafting for acetabular revision: bringing back the bone.
Impaction grafting has been widely promoted on the acetabular side by Schreurs et al,1 with associated bone grafting and a cemented cup. The objectives of impaction grafting are to: 1) transform segmental defects into cavitary defects, 2) obtain a full compaction of the graft, 3) achieve primary stability of the cup, which is anatomically located in the acetabulum, and 4) restore bone stock. Th...
متن کاملMorsellized bone grafting compensates for femoral bone loss in revision total knee arthroplasty. An experimental study.
This study was undertaken to examine the contribution of uncontained morsellized bone graft to the structural properties of a femoral reconstruction in total knee arthroplasty and to serve as a basis for an in vivo animal study. Ten human distal femora with a standard unicondylar uncontained medial bone defect were prepared to fit a femoral component of a cruciate sacrificing TKA. A cyclic axia...
متن کاملEffect of Gamma Irradiation on the Mechanical Properties of Morselised Allograft
INTRODUCTION: Impaction grafting is a common procedure in the reconstruction of cavity defects. Concerns regarding sterility of the graft material may require gamma irradiation prior to implantation. The grafts’ mechanical properties play an important role in surgical handling and in-vivo response. Gamma irradiation adversely affects the mechanical properties in a dose dependent fashion in cort...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical materials research
دوره 58 5 شماره
صفحات -
تاریخ انتشار 2001