The effect of lung-size mismatch on mechanical ventilation tidal volumes after bilateral lung transplantation.
نویسندگان
چکیده
OBJECTIVES Mechanical ventilation tidal volumes are usually set according to an estimate of patient size in millilitres (ml) per kilogram (kg) body weight. We describe the relationship between donor-recipient lung-size mismatch and postoperative mechanical ventilation tidal volumes according to recipient- and donor-predicted body weights in a cohort of bilateral lung transplant patients. METHODS A most-undersized (10 patients with lowest predicted total lung capacity [pTLC] ratio = pTLC-donor/pTLC-recipient), a most-oversized (10 patients with highest pTLC ratio) and best-matched subset (10 patients with predicted total lung capacity ratio closest to 1.0) were selected within a cohort of 70 patients. All tidal volumes during mechanical ventilation in the first 96 h after bilateral lung transplantation were recorded. Tidal volumes were expressed in ml and ml/kg-recipient-predicted body weights and ml/kg-donor-predicted body weights. RESULTS Postoperative absolute tidal volumes (in ml) were comparable between subsets of patients with undersized, matched and oversized allografts (552 ± 103 vs 581 ± 107 vs 582 ± 104 ml), and tidal volumes in ml/kg-recipient-predicted body weights were also similar (8.8 ± 1.4 vs 9.3 ± 1.1 vs 9.8 ± 2.1). However, tidal volumes in ml/kg-donor-predicted body weights revealed significant differences between undersized, matched, and oversized subsets (11.4 ± 3.1 vs 9.4 ± 1.2 vs 8.1 ± 2.1, respectively; P < 0.05). Two patients developed primary graft dysfunction grade 3, both in the undersized subset. Four patients in the undersized group underwent tracheotomy (vs none in matched and one in oversized subset). CONCLUSIONS During mechanical ventilation after bilateral lung transplantation, undersized allografts received relatively higher tidal volumes compared with oversized allografts when the tidal volumes were related to donor-predicted body weights.
منابع مشابه
Mechanical ventilation with lower tidal volumes and positive end-expiratory pressure prevents pulmonary inflammation in patients without preexisting lung injury.
BACKGROUND Mechanical ventilation with high tidal volumes aggravates lung injury in patients with acute lung injury or acute respiratory distress syndrome. The authors sought to determine the effects of short-term mechanical ventilation on local inflammatory responses in patients without preexisting lung injury. METHODS Patients scheduled to undergo an elective surgical procedure (lasting > o...
متن کاملDiffuse alveolar damage due to inappropriate strategy of mechanical ventilation in an experimental porcine model.
BACKGROUND The aim of the study was to determine how tidal volumes may affect the lung and haemodynamics during mechanical ventilation. MATERIALS AND METHODS With the approval of the Ethics Committee, the study included a total of 24 healthy piglets, average weight 30 kg (range 28-33 kg). The animals were ventilated for 90 minutes under general anaesthesia with two different tidal volume stra...
متن کاملHigher initial tidal volumes associated with the subsequent development of acute lung injury in dose-response relationship
Although ventilation with small tidal volumes is recommended in patients with established acute lung injury, most others receive highly variable tidal volume aimed in part at normalizing arterial blood gas values. We tested the hypothesis that acute lung injury, which develops after the initiation of mechanical ventilation, is associated with known risk factors for ventilator-induced lung injur...
متن کاملVentilation with Lower Tidal Volumes as Compared with Traditional Tidal Volumes for Acute Lung Injury and the Acute Respiratory Distress Syndrome
A BSTRACT Background Traditional approaches to mechanical ventilation use tidal volumes of 10 to 15 ml per kilogram of body weight and may cause stretch-induced lung injury in patients with acute lung injury and the acute respiratory distress syndrome. We therefore conducted a trial to determine whether ventilation with lower tidal volumes would improve the clinical outcomes in these patients. ...
متن کاملShould A Tidal Volume of 6 mL/kg Be Used in All Patients?
It has been shown that mechanical ventilation by itself can cause lung injury and affect outcomes. Ventilator-induced lung injury is associated with high tidal volumes in lungs afflicted with ARDS. However, the question is: Do high tidal volumes have this same effect in normal lungs or lungs that have respiratory compromise stemming from something other than ARDS? Many clinicians believe that a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Interactive cardiovascular and thoracic surgery
دوره 16 3 شماره
صفحات -
تاریخ انتشار 2013