Nonfluoroscopic Endoventricular Electromechanical Three-Dimensional Mapping

نویسندگان

  • Glenn Van Langenhove
  • Ken Kozuma
  • Patrick W. Serruys
چکیده

Biosense-Webster, a Johnson&Johnson Company) is a recently developed technique that enables the acquisition of on-line information on the electrical and mechanical endoventricular functioning of myocardial tissue. 1 The rationale for this new technique is 2-fold. First, none of the currently available in-cathlab methods can distinguish viable from non-viable myocardium. Accepted techniques, such as radionuclide scintigraphy and dobutamine stress echocardiography, may not be readily available, and can not be performed in the cathlab. Second, applications such as myocardial laser revascularization or intramyocardial gene-injection may prove cumbersome when performed using echocardiography or fluoroscopy with only 2-dimensional (2-D) projections available on-line.1 A major pitfall of these latter techniques is indeed the inability to accurately associate the 2-D positioning with a specific endocardial site, quite apart from the high X-ray exposure for both patient and physician when using fluoroscopy.2 Although clinical application of on-line 3-dimensional (3D) echocardiography and magnetic resonance imaging is underway, until recently there has not been a technique for real-time 3-D guiding of intervention tools and assessment of myocardial electromechanical functioning. Nonfluoroscopic electromechanical mapping has become the first navigation technique to accurately determine the trajectory of a tool inside the human heart, to guide the interventional device to a specific site, and to meticulously couple functional and anatomical properties. 1

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New Method for Nonfluoroscopic Endocardial Mapping in Humans

Background—Accurate mapping of the site of origin and activation sequence of a cardiac arrhythmia is essential for a successful catheter ablation procedure. To achieve this, precise and reproducible catheter manipulation is mandatory. The aim of this study was (1) to assess the accuracy of a new nonfluoroscopic mapping system in humans and (2) to report the first result of endocardial activatio...

متن کامل

A Method for Catheter Navigation within Realistic Three-Dimensional Cardiac Anatomy

We recently combined noncontact mapping and intracardiac echocardiography (ICE) in a single cathetersystem that permitted detailed, single-beat, 3-D electricalanatomical imaging of the heart. In the present study we developed a nonfluoroscopic electrode-catheter localization method and integrated it with noncontact electrical-anatomical imaging. The difference in nonfluoroscopic electrode locat...

متن کامل

Ablation of atrial fibrillation using novel 4-dimensional catheter tracking within autoregistered left atrial angiograms.

BACKGROUND We describe a novel fluoroscopy coregistered, 4-dimensional catheter tracking technology (MediGuide Technology [MGT]) used for treatment of patients with atrial fibrillation. The aim of the study was to investigate (1) the feasibility of nonfluoroscopic catheter manipulation within dynamic left atrial chamber models; (2) the integration of the technology into an established electroan...

متن کامل

Nonfluoroscopic Ablation of Atrial Fibrillation Using Cryoballoon.

BACKGROUND The conventional method of cryoballoon ablation of atrial fibrillation involves the use of fluoroscopy for visual guidance. The use of fluoroscopy is accompanied by significant radiation risks to the patient and the medical staff. Herein, we report our experience in performing successful nonfluoroscopic pulmonary vein isolation using cryoballoon ablation in 5 consecutive patients wit...

متن کامل

High resolution MSI-guided multiple monophasic action potential mapping with a single amagnetic catheter

During recent years, catheter ablation has become a method of choice in definitive treatment of cardiac arrhythmias. Prerequisite for successful ablation is the precise localization of the arrhythmogenic substrate underlying the clinical arrhythmia. This is usually done during invasive electrophysiological study (EPS) with multichannel endocardial mapping under fluoroscopic imaging [1,2]. More ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001