RYTSI: The Rochester Institute of Technology–Yale Tip-Tilt Speckle Imager
نویسندگان
چکیده
We have constructed a new speckle imaging system that collects a large number of speckle patterns on the detector area of a large-format CCD. The system is called the RIT-Yale Tip-tilt Speckle Imager (RYTSI) because it uses two galvanometric scanning mirrors to tip and tilt each speckle pattern to a different location on the CCD chip. It therefore solves the bandwidth problem of using CCDs in speckle imaging in a unique way: the mirrors direct speckle patterns across the chip with millisecond accuracy, and the CCD is read out only when the chip is filled with patterns. The instrument was designed to accommodate a variety of detector formats, readout systems, and telescope plate scales; it was initially used at the WIYN Observatory in conjunction with an RIT (Rochester Institute of Technology) 2048 CCD. We present the design of the instrument and a sample of first results, which indicate that the instrument can be expected to recover, with high precision, both astrometric and photometric information for binary and multiple stars.
منابع مشابه
Application of Canonical Correlation Analysis to Identify Regions of Significant Correlation between Symptom Scores and DTI Measures in Schizophrenia
A. M. Michael, V. D. Calhoun, G. D. Pearlson , S. A. Baum, and A. Caprihan MIND Research Network, Albuquerque, NM, United States, Center for Imaging Science, Rochester Institute of Technology, Rochester, NY, United States, ECE, University of New Mexico, Albuquerque, NM, United States, Psychiatry, Yale University, New Haven, CT, United States, Olin Neuropsychiatry Research Center, Institute of L...
متن کاملCFHT Wide eld IR Imager
Some of the scientiic projects and roles which a CFHT wideeeld near-IR imager could fulll are explored. To achieve the scientiic goals it is argued that the eld size should be >20 0 and the array should be at least 6K 6K. The imager should incorporate tip/tilt compensation and automatic focus controls to be competitive with the performance of other 4 and 8m class telescopes.
متن کاملZarankiewicz Numbers and Bipartite Ramsey Numbers
The Zarankiewicz number z(b; s) is the maximum size of a subgraph of Kb,b which does not contain Ks,s as a subgraph. The two-color bipartite Ramsey number b(s, t) is the smallest integer b such that any coloring of the edges of Kb,b with two colors contains a Ks,s in the rst color or a Kt,t in the second color.In this work, we design and exploit a computational method for bounding and computing...
متن کاملFizeau Interferometry Testbed: Wavefront Control
Stellar Imager (SI) is a potential NASA space-based UV imaging interferometer to resolve the stellar disks of nearby stars. SI would consist of 20 30 separate spacecraft flying in formation at the Earth-Sun L2 libration point. Onboard wavefront control would be required to initially align the formation and maintain alignment during science observations and after array reconfiguration. The Fizea...
متن کاملSimultaneous measurement of water flow velocity with fluorescent and speckle imaging technique
The average velocity of water flow has been simultaneously measured with fluorescent and speckle imaging methods. The measured velocities with two methods are in good agreement with each other and it confirms that the speckle imaging method can be used as a confident method to measure the velocity of water flow in a dry leaf. Also the velocity of water flow through thick and thin xylems of a le...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2006