Reference ranges for fetal brain fissure development on 3-dimensional sonography in the multiplanar mode.

نویسندگان

  • Cynthia Maria Soares Alves
  • Edward Araujo Júnior
  • Luciano Marcondes Machado Nardozza
  • Susan Menasce Goldman
  • Luiz Henrique Martinez
  • Wellington P Martins
  • Patrícia Soares Oliveira
  • Antonio Fernandes Moron
چکیده

OBJECTIVES To determine reference ranges for measurements of fetal cerebral fissures by 3-dimensional (3D) sonography in the multiplanar mode and to evaluate the reliability and concordance of these measurements. METHODS A cross-sectional study was conducted on 393 women with normal pregnancies at 22 weeks to 33 weeks 6 days. The distances between the internal bone plate of the fetal calvaria and the sylvian, parieto-occipital, hippocampal, and calcarine fissures were assessed. To obtain the distances for the first 3 fissures, a 3D sweep was made in the axial plane, at the level of the lateral ventricles. To obtain the distance for the calcarine fissure, a coronal sweep was used, at the level of the occipital lobes. To evaluate the correlation between the fissures and gestational age, polynomial regression was performed with adjustments using the coefficient of determination (R(2)). Reliability was determined with intraclass correlation coefficients and concordance with concordance limits. RESULTS The mean distances ± SD to the sylvian, parieto-occipital, hippocampal, and calcarine fissures were 10.42 ± 2.28, 22.38 ± 3.23, 24.88 ± 4.67, and 21.19 ± 2.73 mm, respectively. These distances correlated with gestational age such that the best fit with the linear equation produced R(2) values of 0.582, 0.627, 0.860, and 0.458 for the sylvian, parieto-occipital, hippocampal, and calcarine fissures. Reliability analyses showed intraobserver and interobserver intraclass correlation coefficients of 0.90 to 0.95 and 0.85 to 0.97. The concordance limits were-1.33 to 1.30 and -2.38 to 2.28 mm for the intraobserver evaluation and -1.60 to 2.57 and -3.51 to 2.73 mm for the interobserver evaluation. CONCLUSIONS Cerebral fissures can be measured by 3D sonography at 22 to 33 weeks of pregnancy with acceptable reliability and concordance. Reference ranges for this gestational period have thus been described.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Examination of the fetal brain by transabdominal three-dimensional ultrasound: potential for routine neurosonographic studies.

OBJECTIVE To evaluate the role of transabdominal three-dimensional (3D) ultrasound in the assessment of the fetal brain and its potential for routine neurosonographic studies. METHODS We studied prospectively 202 consecutive fetuses between 16 and 24 weeks' gestation. A 3D ultrasound volume of the fetal head was acquired transabdominally. The entire brain anatomy was later analyzed using the ...

متن کامل

Clinical application of three-dimensional ultrasound in fetal brain assessment.

AIM To clarify the usefulness of three-dimensional (3D) ultrasound in the assessment of the fetal head and brain, according to 3D ultrasound surface reconstruction, multiplanar image analysis, three-dimensional angiography, and volume calculation. METHODS We examined 326 normal fetuses between 10 and 40 weeks of gestation using 3D ultrasound (Voluson, 530D, Medison, Seoul, Korea), mainly with...

متن کامل

Reference intervals of fetal cisterna magna volume by two-dimensional method using the multiplanar mode of three-dimensional ultrasonography*

OBJECTIVE To establish reference intervals for the fetal cisterna magna volume by means of two-dimensional (2D) method using the multiplanar mode of three-dimensional ultrasonography. MATERIALS AND METHODS Cross-sectional study with 224 healthy pregnant women between the 17th and 29th gestational weeks. The volume was automatically obtained by multiplying the three major axes in axial and sag...

متن کامل

I-42: Advanced Ultrasonic Techniques in The Assessment of Early Human Development

Background: To evaluate the role of 3D, 4D and color Doppler ultrasound (US) in the assessment of early human development. Materials and Methods: 380 women with uncomplicated early pregnancy between 5 and 14 weeks were evaluated by 3D, 4D and color Doppler US. Results: Regression analysis revealed exponential rise of the gestational sac volume with gestational age throughout the first trimester...

متن کامل

مقایسه یافته های سونوگرافیک و MRI در ناهنجاری های جنینی

Background and purpose: Ultra sonography is the method of choice in pre-natal diagnosis of fetal anomalies however, sonography has limitations in oligohydramnios, maternal obesity and complex fetal anomalies. MRI, is a method with high contrast resolution, large FOV for fetus, placenta and uterine, along with multiplanar images. The aim of our study is to compare the sonographic and MRI findi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine

دوره 32 2  شماره 

صفحات  -

تاریخ انتشار 2013