"Silent" MRI with soft gradient pulses.

نویسندگان

  • F Hennel
  • F Girard
  • T Loenneker
چکیده

A method to reduce the acoustic noise generated by gradient systems in magnetic resonance imaging (MRI) is proposed based on the linear response theory. Since the acoustic frequency response function of typical gradient coils is low in the range below 200 Hz, the noise level can be significantly reduced by using gradient pulse sequences whose spectra are limited to this frequency range. Such "soft," i.e., band-limited, pulse shapes can be designed using sinusoidal ramps individually adjusted to available delays. "Silent" versions of three basic MRI sequences [gradient-echo (GE), spin-echo (SE), and rapid acquisition with relaxation enhancement (RARE)] were programmed on 2 and 3 T whole-body scanners. High-quality images could be acquired at noise levels as low as 40 dBA (GE and SE) and 60 dBA (RARE).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mri Sequences

An MRI sequence is an ordered combination of RF and gradient pulses designed to acquire the data to form the image. In this chapter I will describe the basic gradient echo, spin echo and inversion recovery sequences used in MRI. The data to create an MR image is obtained in a series of steps. First the tissue magnetisation is excited using an RF pulse in the presence of a slice select gradient....

متن کامل

Silent stroke in patients with acute thrombotic stroke

Introduction: Brain stroke is the most common neurologic disorder and also the most common cause of mortality and morbidity in neurtologic patients. Thanks to new methods of radiography such as MRI, brain vascular lesions including silent stroke are demonstrated more carefully. This study considers the frequency of silent stroke in patients with acute thrombotic stroke in Rafsanjan by using M...

متن کامل

Silent subcortical brain infarction

Introduction: The silent brain lesions detected by MRI were fairly common not only in first-ever stroke but also in normal elderly subjects. Some recent studies show the possible role of silent sub-cortical brain infarction in ischemic stroke. The aim of this study was to evaluate the frequency of silent sub-cortical brain infarction in acute first-ever ischemic stroke. Methods: In this descrip...

متن کامل

MRI of Soft Tissue Tumors and Tumor Mimickers

Magnetic resonance imaging (MRI) has become a vital part of the routine work up of a patient with a suspected soft-tissue tumor of the musculoskeletal system. Unlike for bone lesions, plain radiography and CT are of little help in evaluating noncalcified tumors in soft tissue. True multiplanar capability and unparalleled capacity for softtissue contrast make MRI superbly suited to this particul...

متن کامل

Acoustic noise characteristics of a 4 Telsa MRI scanner.

PURPOSE To quantify the acoustic noise characteristics of a 4 Tesla MRI scanner, and determine the effects of structural acoustics and gradient pulse excitations on the sound field so that feasible noise control measures can be developed. MATERIALS AND METHODS Acoustic noise emissions were measured in the ear and mouth locations of a typical adult. The sound pressure measurements were acquire...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 42 1  شماره 

صفحات  -

تاریخ انتشار 1999