Comparison of magnetic resonance volume flow rates, angiography, and carotid Dopplers. Preliminary results.

نویسندگان

  • R L Levine
  • P A Turski
  • K A Holmes
  • T M Grist
چکیده

BACKGROUND AND PURPOSE We compared the results of conventional angiography, carotid Doppler, and magnetic resonance angiography volume flow rates to determine the clinical utility of volume flow rate assessment of blood flow to the anterior circulation in patients with carotid occlusive disease. METHODS From 11 symptomatic patients, a total of 22 extracranial carotid arteries were studied with all three techniques. The studies were independently read, and regression analysis was used to compare the measurements. RESULTS Carotid Doppler measurements of the distal extracranial carotid arteries were proportional to the inverse of the extracranial carotid volume flow rate (r = .53, R2 = 29%, P < .01), volume flow rates were proportional to the inverse of measured percent stenosis on angiography (r = .84, R2 = 71%, P < .01), and Dopplers were proportional to angiography (r = .94, R2 = 90%, P < .01). Symptomatic Doppler systolic velocity was significantly higher (P < .002), symptomatic measured stenosis was significantly higher (P < .002), and symptomatic volume flow rate was significantly lower (P < .01) than their respective asymptomatic-side values. These preliminary observations, however, may well change once a large data set, especially one in which more patients with high-grade carotid stenosis are included, is studied. CONCLUSIONS Assessment of carotid volume flow rates by magnetic resonance angiography quantifies flow reduction secondary to atherosclerotic occlusive disease. The easily obtained flow data add both documentation of arterial flow characteristics related to internal carotid stenosis and information regarding the adequacy of collateral pathways.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preliminary Results

Background and Purpose We compared the results of conventional angiography, carotid Doppler, and magnetic resonance angiography volume flow rates to determine the clinical utility of volume flow rate assessment of blood flow to the anterior circulation in patients with carotid occlusive disease. Methods From 11 symptomatic patients, a total of 22 extracranial carotid arteries were studied with ...

متن کامل

Blood Flow Simulation in an Aorta with a mild coarctation Using Magnetic Resonance Angiography and Finite Volume Method

Coarctation of the aorta is one of the five main congenital cardiovascular failures, accounting for 6–8 percent of these failures. This research aimed to simulate the blood flow of a seventeen-year-old male teen with a mild coarctation at one-third of his aorta's descending branch. The simulation was performed by extracting the domain and the input pulsatile velocity signal as the boundary cond...

متن کامل

New Methods for Computational Fluid Dynamics Modeling of Carotid Artery from Magnetic Resonance Angiography

Computational fluid dynamics (CFD) models of the carotid artery are constructed from contrast-enhanced magnetic resonance angiography (MRA) using a deformable model and a surface-merging algorithm. Physiologic flow conditions are obtained from cine phase-contrast MRA at two slice locations below and above the carotid bifurcation. The methodology was tested on image data from a rigid flow-throug...

متن کامل

Magnetic resonance angiography of cerebral arteries after neonatal venoarterial and venovenous extracorporeal membrane oxygenation.

BACKGROUND AND PURPOSE In newborns with severe respiratory failure, extracorporeal membrane oxygenation (ECMO) has been proven to improve survival. With venoarterial ECMO, the right common carotid artery is ligated, whereas with venovenous ECMO, this carotid artery remains intact. The authors present the magnetic resonance angiography (MRA) evaluation of cerebral hemodynamics in a case of venoa...

متن کامل

Validation of cerebral arteriovenous malformation hemodynamics assessed by DSA using quantitative magnetic resonance angiography: preliminary study.

BACKGROUND The hemodynamic evaluation of cerebral arteriovenous malformations (AVMs) using DSA has not been validated against true flow measurements. OBJECTIVE To validate AVM hemodynamics assessed by DSA using quantitative magnetic resonance angiography (QMRA). MATERIALS AND METHODS Patients seen at our institution between 2007 and 2016 with a supratentorial AVM and DSA and QMRA obtained b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 25 2  شماره 

صفحات  -

تاریخ انتشار 1994