Aerosol deposition characteristics in distal acinar airways under cyclic breathing conditions.
نویسندگان
چکیده
Although the major mechanisms of aerosol deposition in the lung are known, detailed quantitative data in anatomically realistic models are still lacking, especially in the acinar airways. In this study, an algorithm was developed to build multigenerational three-dimensional models of alveolated airways with arbitrary bifurcation angles and spherical alveolar shape. Using computational fluid dynamics, the deposition of 1- and 3-μm aerosol particles was predicted in models of human alveolar sac and terminal acinar bifurcation under rhythmic wall motion for two breathing conditions (functional residual capacity = 3 liter, tidal volume = 0.5 and 0.9 liter, breathing period = 4 s). Particles entering the model during one inspiration period were tracked for multiple breathing cycles until all particles deposited or escaped from the model. Flow recirculation inside alveoli occurred only during transition between inspiration and expiration and accounted for no more than 1% of the whole cycle. Weak flow irreversibility and convective transport were observed in both models. The average deposition efficiency was similar for both breathing conditions and for both models. Under normal gravity, total deposition was ~33 and 75%, of which ~67 and 96% occurred during the first cycle, for 1- and 3-μm particles, respectively. Under zero gravity, total deposition was ~2-5% for both particle sizes. These results support previous findings that gravitational sedimentation is the dominant deposition mechanism for micrometer-sized aerosols in acinar airways. The results also showed that moving walls and multiple breathing cycles are needed for accurate estimation of aerosol deposition in acinar airways.
منابع مشابه
The effect of heterogeneity of lung structure on particle deposition in the rat lung.
Differences in particle deposition patterns between human and rat lungs may be attributed primarily to their differences in breathing patterns and airway morphology. Heterogeneity of lung structure is expected to impact acinar particle deposition in the rat. Two different morphometric models of the rat lung were used to compute particle deposition in the acinar airways: the multiple-path lung (...
متن کاملAlveolar duct expansion greatly enhances aerosol deposition: a three-dimensional computational fluid dynamics study
Obtaining in vivo data of particle transport in the human lung is often difficult, if not impossible. Computational fluid dynamics (CFD) can provide detailed information on aerosol transport in realistic airway geometries. This paper provides a review of the key CFD studies of aerosol transport in the acinar region of the human lung. It also describes the first ever three-dimensional model of a...
متن کاملAerosol bolus dispersion in acinar airways--influence of gravity and airway asymmetry.
The aerosol bolus technique can be used to estimate the degree of convective mixing in the lung; however, contributions of different lung compartments to measured dispersion cannot be differentiated unambiguously. To estimate dispersion in the distal lung, we studied the effect of gravity and airway asymmetry on the dispersion of 1 μm-diameter particle boluses in three-dimensional computational...
متن کاملFlow field analysis in expanding healthy and emphysematous alveolar models using particle image velocimetry.
Particulates that deposit in the acinus region of the lung have the potential to migrate through the alveolar wall and into the blood stream. However, the fluid mechanics governing particle transport to the alveolar wall are not well understood. Many physiological conditions are suspected to influence particle deposition including morphometry of the acinus, expansion and contraction of the alve...
متن کاملMapping PET-measured triamcinolone acetonide (TAA) aerosol distribution into deposition by airway generation.
The three dimensional (3D) distribution of inhaled drugs was measured using Positron Emission Tomography (PET) (Berridge, M.S, Muswick, G.J., Lee, Z., Leisure, G.L., Nelson, A.D., Muzic, R.F. Jr., Miraldi, F., Heald, D.L., 1997. PET evaluation of Azmacort(R) ([C-11]triamcinolone acetonide) dose administration. J. Nucl. Med. 38 (5) Suppl., 4-5). Data analysis was based upon regional ratios or pe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 110 5 شماره
صفحات -
تاریخ انتشار 2011