Diurnal variation of choroidal thickness in normal, healthy subjects measured by spectral domain optical coherence tomography.

نویسندگان

  • Colin S Tan
  • Yanling Ouyang
  • Humberto Ruiz
  • SriniVas R Sadda
چکیده

PURPOSE To describe the pattern and magnitude of diurnal variation of choroidal thickness (CT), its relation to systemic and ocular factors, and to determine the intervisit reproducibility of diurnal patterns. METHODS A prospective study was conducted on 12 healthy volunteers who each underwent sequential ocular imaging on two separate days at five fixed, 2-hour time intervals. Spectral domain optical coherence tomography (OCT) with enhanced depth imaging and image tracking was performed using a standardized protocol. Choroidal and retinal thicknesses were independently assessed by two masked graders. CT diurnal variation was assessed using repeated-measures ANOVA. RESULTS A significant diurnal variation in CT was observed, with mean maximum CT of 372.2 μm, minimum of 340.6 μm (P < 0.001), and mean diurnal amplitude of 33.7 μm. Retinal thickness (mean, 235.0 μm) did not exhibit significant diurnal variation (P = 0.621). The amplitude of CT variation was significantly greater for subjects with thicker morning baseline CT compared with those with thin choroids (43.1 vs. 10.5 μm, P < 0.001). There were significant correlations between amplitude of CT and age (P = 0.032), axial length (P < 0.001), and spherical equivalent (P < 0.001). The change in CT also correlated with change in systolic blood pressure (P = 0.031). Comparing CT on two different days, a similar diurnal pattern was observed, with no significant difference between corresponding measurements at the same time points (P = 0.180). CONCLUSIONS There is significant diurnal variation of CT, with good intervisit reproducibility of diurnal patterns on two different days. The amplitude of variation varies with morning baseline CT, and is correlated with age, axial length, refractive error, and change in systolic blood pressure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diurnal Choroidal Thickness Changes in Normal Eyes of Turkish People Measured by Spectral Domain Optical Coherence Tomography

Purpose. To analyse the diurnal variation of central choroidal thickness (CCT) in healthy emetropic patients during working hours. Methods. Fifty healthy young emmetrpic volunteers were included in this study. CCT was measured at 9 AM and 4 PM with spectral domain optical coherence tomography (Spectralis, Heidelberg Engineering) with enhanced depth imaging. Diurnal variation of CCT, the correla...

متن کامل

Retinal Ganglion Cell Complex in Alzheimer Disease: Comparing Ganglion Cell Complex and Central Macular Thickness in Alzheimer Disease and Healthy Subjects Using Spectral Domain-Optical Coherence Tomography

Introduction: Alzheimer disease (AD) is the most common form of dementia worldwide. The modalities to diagnose AD are generally expensive and limited. Both the central nervous system (CNS) and the retina are derived from the cranial neural crest; therefore, changes in retinal layers may reflect changes in the CNS tissue. Optical coherence tomography (OCT) machine can show delicate retinal layer...

متن کامل

Comparison of Choroidal Thickness in Psoriasis and Control Groups Using Optical Coherence Tomography

Background and Objective: One of the most common extracutaneous complications in psoriasis patients is ocular complications, which is controversial concerning its effect on choroidal thickness. This study aimed to compare the psoriasis patients with healthy individuals in terms of the thickness of the choroidal layer using the optical coherence tomography technique. Materials and Methods: In t...

متن کامل

Choroidal thickness in patients with diabetic retinopathy analyzed by spectral-domain optical coherence tomography.

PURPOSE This study was designed to examine choroidal thickness in patients with diabetes using spectral-domain optical coherence tomography. METHODS Forty-nine patients (49 eyes) with diabetes and 24 age-matched normal subjects underwent high-definition raster scanning using spectral-domain optical coherence tomography with frame enhancement software. Patients with diabetes were classified in...

متن کامل

Comparison of Choroidal Thickness in Patients with Diabetes by Spectral-domain Optical Coherence Tomography

PURPOSE To evaluate choroidal thickness in diabetes patients using spectral-domain optical coherence tomography. METHODS We examined 203 eyes of 203 diabetic participants and 48 eyes of 48 healthy controls. The choroidal thickness at the foveal lesion was measured by enhanced-depth imaging optical coherence tomography. The participants were grouped according to diabetic retinopathy grade: no ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 53 1  شماره 

صفحات  -

تاریخ انتشار 2012