In vitro assessments of reverse glenoid stability using displacement gages are misleading - recommendations for accurate measurements of interface micromotion.

نویسندگان

  • Philippe Favre
  • Scott Perala
  • Peter Vogel
  • Sandro F Fucentese
  • Jonathan R Goff
  • Christian Gerber
  • Jess G Snedeker
چکیده

BACKGROUND Baseplate micromotion of the reverse shoulder glenoid component can lead to implant loosening. We hypothesized that a remotely positioned displacement gage measures elastic deformation of the system rather than actual micromotion at the implant/bone interface. METHODS Reverse glenoid components were implanted into polyurethane blocks of 3 different densities. A 700 N compressive load was maintained and a vertical 700 N shear load was applied for 1000 cycles. In addition to the typical gage measurement, a digital image analysis of micromotion at the implant/block interface using high resolution cameras was performed. The measurements were validated on human specimens. A finite element model was implemented to study the isolated effect of block deformation on baseplate displacements. FINDINGS With the gage, typically reported micromotions were measured. Two orders of magnitude lower micromotions were detected using interface image-based analysis. The finite element simulation showed that elastic deformation alone can cause micromotion magnitudes as measured with displacement gages. Polyurethane blocks of 20 and 15 lbs per cubic foot density best reproduced micromotions as measured on human specimens. INTERPRETATION We found considerably less relative micromotion at the implant/bone interface than previously assumed. Gage measurements quantify elastic deformation and not true interface micromotion. High resolution digital imaging at the implant/bone interface is strongly recommended for an accurate assessment of reverse glenoid component micromotion. Tests should further adopt 20 or 15 pcf bone test surrogates. Further studies are required to identify the failure modes encountered in vivo, and a corresponding in vitro testing methodology can then be developed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of baseplate size on primary glenoid stability and impingement-free range of motion in reverse shoulder arthroplasty

BACKGROUND Use of a baseplate with a smaller diameter in reverse shoulder arthroplasty is increasing, especially in patients with a small glenoid or glenoid wear. However, the effect of a smaller baseplate on stability of the glenoid component has not been evaluated. Thus, the purpose of this study was to determine whether a smaller baseplate (25 mm) is beneficial to the initial stability of th...

متن کامل

Analysis of reverse total shoulder joint forces and glenoid fixation.

Reverse total shoulder arthroplasty (rTSA) implants are intended to restore stability and function to shoulders with rotator cuff deficiency. The implant consists of a glenosphere projecting from a glenoid baseplate and articulating in a socket at the proximal end of a humeral component. Despite the demonstrated clinical efficacy, little information is available regarding the joint forces about...

متن کامل

On the Displacement-Stress Continuous Finite Elements

For the analysis of composite media, three different compatible and mixed finite element formulations are presented which apriori enforce the continuity of stresses as well as displacements at the element interfaces. The formulations are applied for the analysis of hi-material interfaces in two problems often encountered in the field of orthopaedic biomechanics, that is the fixation analysis in...

متن کامل

Novel Method for Testing Cementless Tibial Components Using Micromotion and Impedance Vibration Analysis

INTRODUCTION: The initial mechanical stability of cementless implants is critical to achieve successful osseointegration through minimization of deleterious micromotion. Controversy exists regarding the most reliable and appropriate methodology for in vitro mechanical testing of implants used to guide design and performance of cementless total knee replacement. Mechanical testing methods vary w...

متن کامل

An in vitro study comparing limited to full cementation of polyethylene glenoid components

BACKGROUND Glenoid component survival is critical to good long-term outcomes in total shoulder arthroplasty. Optimizing the fixation environment is paramount. The purpose of this study was to compare two glenoid cementing techniques for fixation in total shoulder arthroplasty. METHODS Sixteen cadaveric specimens were randomized to receive peg-only cementation (CPEG) or full back-side cementat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical biomechanics

دوره 26 9  شماره 

صفحات  -

تاریخ انتشار 2011