Intrapartum Digital Vaginal Examination for Fetal Head Position

نویسنده

  • Viola YT CHAN
چکیده

Objective: To investigate the accuracy of intrapartum digital vaginal examination in assessing fetal head position during active labour, and to compare accuracy of intrapartum digital vaginal examination for fetal head position between specialist trainee doctors and specialist obstetricians. Methods: A total of 100 patients at term with normal singleton cephalic-presenting fetuses were recruited. Transabdominal ultrasound examination to determine the position of the fetal head was performed by a trained sonographer, followed immediately by digital vaginal examination by attending specialist trainee doctor or specialist obstetrician. Both examiners were blinded to each other’s findings. A total of 112 measurements were generated. Statistical analyses included Chi-square test, Kappa test, and logistic regression analysis. p Values of <0.05 were considered statistically significant. Results: Digital vaginal examinations were completely consistent with ultrasound assessment in 34 (30%) cases. Assuming that the fetal head position was correct provided it was within ± 45 degrees of the ultrasound assessment, digital examination was accurate in 77 (69%) of cases. The respective rate of agreement between the two assessment methods by specialist trainee doctors versus specialist obstetricians was 67% and 75% (p=0.69). There were no significant associations between accuracy of digital vaginal examination and maternal and labour characteristics. Conclusions: Fetal head position during active labour determined by digital vaginal examination was accurate in about two-thirds of all cases, with only one-third of cases being in complete agreement with that obtained by ultrasound assessment. There was no statistically significant difference in accuracy of digital vaginal examination by specialist trainees compared with that by specialist obstetricians. Hong Kong J Gynaecol Obstet Midwifery 2015; 15(1):23-8

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of transvaginal digital examination with intrapartum sonography to determine fetal head position before instrumental delivery.

OBJECTIVE To investigate the accuracy of intrapartum transvaginal digital examination in defining the position of the fetal head before instrumental delivery. PATIENTS AND METHODS In 64 singleton pregnancies undergoing instrumental delivery the fetal head position was determined by transvaginal digital examination by the attending obstetrician. Immediately after or before the clinical examina...

متن کامل

Role of Intrapartum Ultrasound in Modern Obstetrics

Intrapartum ultrasound has become more popular over the last decade. It provides a more objective assessment of fetal head position and station than traditional digital vaginal examination, which is now known to be inaccurate. Correct identification of fetal head position is particularly useful before instrumental delivery, although it should not be used in the first stage of labour to predict ...

متن کامل

Fetal Head Position during the First Stage of Labor: Comparison between Vaginal Examination and Transabdominal Ultrasound

Introduction. Recent evidence indicates that clinical examination, for determination of fetal head position, is subjective and inaccurate. Present study was aimed to compare transabdominal ultrasound for fetal head position with vaginal examination during first stage of labor. Material and Methods. This prospective study was performed at a tertiary center during a two-year period. Before or aft...

متن کامل

Intrapartum ultrasound: A useful method for evaluating labor progress and predicting operative vaginal delivery

The last step of a successful pregnancy is the safe delivery of the fetus. An important question is if the delivery should vaginal or operative. In addition to the use of conventional antenatal ultrasound, the use of intrapartum ultrasound to evaluate fetal head station, position, cervical ripening, and placental separation is promising. This review evaluates and summarizes the usefulness of in...

متن کامل

Intrapartum sonography – eccentricity or necessity?

Ultrasonography has been extensively used in obstetrics and gynecology since 1980's. It found application in pediatric gynecology, procreation period, post-menopause, pregnancy monitoring and after delivery. Although the first reports on the use of ultrasonography in assessing delivery mechanism were published in 1990's, yet to date labor progress is evaluated by means of physical examination i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015