A new device to test cutting efficiency of mechanical endodontic instruments
نویسندگان
چکیده
BACKGROUND The purpose of the present study was to introduce a new device specifically designed to evaluate the cutting efficiency of mechanically driven endodontic instruments. MATERIAL AND METHODS Twenty new Reciproc R25 (VDW, Munich, Germany) files were used to be investigated in the new device developed to test the cutting ability of endodontic instruments. The device consists of a main frame to which a mobile plastic support for the hand-piece is connected and a stainless-steel block containing a Plexiglas block against which the cutting efficiency of the instruments was tested. The length of the block cut in 1 minute was measured in a computerized program with a precision of 0.1mm. The instruments were activated by using a torque-controlled motor (Silver Reciproc; VDW, Munich, Germany) in a reciprocating movement by the "Reciproc ALL" program (Group 1) and in counter-clockwise rotation at 300 rpm (Group 2). Mean and standard deviations of each group were calculated and data were statistically analyzed with a one-way ANOVA test (P<0.05). RESULTS Reciproc in reciprocation (Group 1) mean cut in the Plexiglas block was 8.6 mm (SD=0.6 mm), while Reciproc in rotation mean cut was 8.9 mm (SD=0.7 mm). There was no statistically significant difference between the 2 groups investigated (P>0.05). CONCLUSIONS The cutting testing device evaluated in the present study was reliable and easy to use and may be effectively used to test cutting efficiency of both rotary and reciprocating mechanical endodontic instruments.
منابع مشابه
Determination of scratching energy index for Cerchar abrasion test
Rock abrasivity is an essential factor for selecting cutting tools, estimating tool wear and life, and ultimately, matching various mechanized excavation systems with a given geologic condition. It also assists engineers to determine economic limits of different cutting tools and machines used in civil and mining projects. The Cerchar abrasion test is a simple and most widely used method for ro...
متن کاملEffect of cryogenic treatment on nickel-titanium endodontic instruments.
AIM To investigate the effects of cryogenic treatment on nickel-titanium endodontic instruments. The null hypothesis was that cryogenic treatment would result in no changes in composition, microhardness or cutting efficiency of nickel-titanium instruments. METHODOLOGY Microhardness was measured on 30 nickel-titanium K-files (ISO size 25) using a Vicker's indenter. Elemental composition was me...
متن کاملSimulation and Experiment on Conveying Device of Cutting System of Small Sugarcane Harvester (RESEARCH NOTE)
The main problem is less efficiency and blocking during sugarcane harvesting in hilly areas. This paper researched the cutting and transporting system of a small sugarcane harvester using virtual prototype technology. The dynamics simulation analyses were carried out to study the transporting status with different friction coefficients between the sugarcane and the spiral and different numbers ...
متن کاملDesign Features of Rotary Instruments in Endodontics
The last decade has been witness to phenomenal growth in endodontic technology. The introduction of these new technologies has resulted in endodontics becoming easier, faster and most importantly, better. Principal among these is Nickel Titanium (NiTi) rotary instrumentation that results in consistent, predictable, and reproducible shaping. The purpose of this article is to review the design fe...
متن کاملCutting efficiency of Reciproc and waveOne reciprocating instruments.
INTRODUCTION The aim of the present study was to evaluate the cutting efficiency of 2 new reciprocating instruments, Reciproc and WaveOne. METHODS Twenty-four new Reciproc R25 and 24 new WaveOne Primary files were activated by using a torque-controlled motor (Silver Reciproc) and divided into 4 groups (n = 12): group 1, Reciproc activated by Reciproc ALL program; group 2, Reciproc activated b...
متن کامل