4-D PET joint image reconstruction/non-rigid motion estimation with limited MRI prior information
نویسندگان
چکیده
Institute of Nuclear Medicine–UCL, University College London, London NW1 2BU, UK Motion compensated gated PET image reconstruction methods include jointreconstruction (JR) and indirect reconstruction (IR) with pre-estimated motion from MRI (MRI-IR). JR suffers from poor PET data quality whereas MRI-IR requires highquality MRI volumes at each gate. We propose a penalised maximum-likelihood approach combining JR and MRI-IR. Our method is referred to as minimal MRI prior JR (MP-JR). The M gates data are stored in g = [g1; ...; gM] where gm is the measurement vector at gate m. Each gm is a Poisson distributed vector of parameter g f P f r ( , ) ( ) m m m W where P is the projector, W(am) is the m-th motion of parameter am, rm is the m-th average random/scatter vector and f is the activity at m = 1. JR is achieved with (1).
منابع مشابه
Impact of Various Image Reconstruction Methods on Joint Compensation of Respiratory Motion and Partial Volume Effects in Whole-Body 18F-FDG PET/CT Imaging: Patients with Non-Small Cell Lung Cancer
Background: The present study aims to assess the impact of various image reconstruction methods in 18F-FDG PET/CT imaging on the quantification performance of the proposed technique for joint compensation of respiratory motion and partial volume effects (PVEs) in patients with non-small cell lung cancer. Materials and Methods: An image-based deconvolution technique was proposed, incorporating w...
متن کاملList-Mode Affine Rebinning for Respiratory Motion Correction in PET Cardiac Imaging
Positron Emission Tomography (PET) is an established functional imaging modality but its practical deployment is hampered by motion artefacts. This paper proposes a method for correcting reconstructed PET images through a list-mode rebinning process. Respiratory motion is compensated for by applying 2D affine transforms to the respiratory gated sequence of line-ofresponse events prior to image ...
متن کاملMotion Aspects in Joint Image Reconstruction and Nonrigid Motion Estimation
MOTION ASPECTS IN JOINT IMAGE RECONSTRUCTION AND NONRIGID MOTION ESTIMATION by Se Young Chun Chair: Jeffrey A. Fessler Many medical imaging applications often require relatively long image acquisition times to form high-SNR images. However, long scan times can lead to motion artifacts. Conventional acquisition and reconstruction methods must sacrifice enough measurements for less motion artifac...
متن کاملJoint image reconstruction and nonrigid motion estimation with a simple penalty that encourages local invertibility
Motion artifacts are a significant issue in medical image reconstruction. There are many methods for incorporating motion information into image reconstruction. However, there are fewer studies that focus on deformation regularization in motioncompensated image reconstruction. The usual choice for deformation regularization has been penalty functions based on the assumption that tissues are ela...
متن کاملCompensation for nonrigid motion using B-spline image registration in simultaneous MR-PET
Introduction Motion correction in PET imaging has been actively researched in the PET community, however obtaining accurate motion estimation is challenging. Motion has been usually estimated from CT images in PET/CT acquisition or from the PET data themselves. However, both modalities have limited accuracy for estimating motion because CT suffers from poor soft tissue contrast while PET has po...