Planar Butler Matrix Technology for 7 Tesla MRI

نویسندگان

  • P. Yazdanbakhsh
  • A. Bitz
  • S. Orzada
  • O. Kraff
  • M. E. Ladd
  • K. Solbach
چکیده

Introduction Variation of the B1 field distribution at high field causes variation of the flip angles inside the patient’s body which leads to shading in the acquired images. Numerous methods have been proposed to mitigate B1 inhomogeneity. More recently, it was shown that “B1 shimming” can be performed using multiple transmitters [1,2], but utilizing these additional transmit channels effectively is extremely critical. Arrays formed from the orthogonal modes of a Degenerate Birdcage Coil (DBC) have been shown to have beneficial properties [3, 4]. In order to access these modes simultaneously, a Butler Matrix [5] is used to drive the individual rungs of the DBC in linear combinations to form the uniform birdcage mode as well as higher gradient modes. The other advantage of using the modes of a birdcage coil excited by a Butler Matrix is that they form naturally decoupled orthogonal modes that do not require decoupling strategies [6]. The Butler Matrix has also been found to provide reflection coefficients that are insensitive to the load [7]. In this work a novel reduced-size 8×8 high-power Butler Matrix has been designed and fabricated at 300 MHz to excite a coil array in 7 Tesla MRI. Methods and Construction The realization of an 8×8 Butler Matrix, Fig.1 (a), requires a combination of 90○ hybrid couplers (3dB) and fixed phase shifters. Line crossovers of conventional Butler Matrix designs are one of the main drawbacks, since they may add several undesired effects. To overcome this problem, a new layout of the matrix has been designed as shown in Fig.1 (b) which uses ports at the edges as well as at the center of the matrix. To design the 90○ hybrid couplers, Branch-Line (BL) couplers were used, Fig. 2(a), because of their high power and high voltage capability. BL couplers split the RF power equally between their outputs with a relative phase of 90○. Considering the dimensions of the BL coupler, the length of the branch line and series line is generally chosen to be a quarter wavelength at the design frequency. Our realization is based on microstrip technology and has been designed on two different substrates: (1) RO4003 with εr = 3.38, tanδ=0.0027 and a thickness of h=1.524 mm, and (2) RO3010 with higher permittivity of εr = 10.2, tanδ=0.0023 and h=1.28 mm. For the RO4003 substrate, this results in a branch line length of 13.59 cm, a series line length of 13.21 cm, and a total size of 14.7 ×16.2 cm for the BL coupler. To realize an 8×8 Butler Matrix at 300 MHz, constructed from twelve BL couplers, the size of each coupler should be reduced. Therefore, a novel compact size BL coupler using chamfered bends to fold the branches and reduce the total size of the coupler was designed, see Fig 2(b). Using this method, the size of the BL coupler was reduced to 10.7×9 cm. This coupler was implemented in the layout environment of the Agilent ADS software suite and has been optimized, realized (cf. Fig. 3(a)), and tested. If the full Butler Matrix network, shown in Fig 1(b), were to be realized in just one board, the physical dimensions of the Butler Matrix would be 60×65 cm, which is difficult to accommodate in the bore of the MR system. To reduce the total size of the manufactured Butler Matrix, it was split into 6 substrates with cable connections. The output phase shifters and related BL couplers were realized on four separate substrates, with two substrates each stacked above and below the two main substrates (each main substrate includes four BL couplers), as shown in Fig 4 (a). The size of this Butler Matrix is 28(length) × 22(width) × 18 (height) cm. RO3010 substrate with the higher permittivity was considered for the next experiment. The size of individual BL couplers, shown in Fig 3(b), has been reduced to 5.8 × 4cm using this board. The Butler Matrix network was designed (in ADS layout) and realized in one board, Fig 4(b), and its physical dimensions have been reduced to 27cm× 27 cm. Fig. 1:(a) Planar 8×8 Butler Matrix block diagram. (b) Butler Matrix without any crossing

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Phase Error Corrections for Microstrip 8×8 Butler Matrix Used in 7 Tesla MRI

Abstract—This paper describes a method to estimate the fixed phase shifts of the Microstrip 8×8 Butler Matrix, realized in one substrate board which is designed and fabricated for our 7-Tesla Magnetic Resonance Imaging (MRI) system. This method is based on a global optimization problem to minimize a cost function including a variety of 64 functions as a function of the fixed phase shifts of the...

متن کامل

Design and fabrication of a realistic anthropomorphic heterogeneous head phantom for MR purposes

OBJECTIVE The purpose of this study is to design an anthropomorphic heterogeneous head phantom that can be used for MRI and other electromagnetic applications. MATERIALS AND METHODS An eight compartment, physical anthropomorphic head phantom was developed from a 3T MRI dataset of a healthy male. The designed phantom was successfully built and preliminarily evaluated through an application tha...

متن کامل

Design and Implementation of a Planar 4 × 4 Butler Matrix in Siw Technology for Wide Band High Power Applications

This paper introduces a novel design of Butler matrix in substrate integrated waveguide (SIW) technology with wide frequency band characteristics. Butler matrices are particularly useful in advanced antenna design and characteristics such as wideband operation, power handling, manufacturing, integration, cost, etc. are typical issues to be addressed in many applications. The proposed planar 4 ×...

متن کامل

Sensitivity Encoded Proton Echo Planar Spectroscopic Imaging (PEPSI) in Human Brain at 7 Tesla

choline, glutamate and inositol (32x32 matrix) with 2-fold SENSE acceleration. Fig.3 Fully sampled PEPSI maps of non-suppressed water (64x64 matrix) and metabolite maps of NAA, creatine, choline, glutamate and inositol (32x32 matrix), acquired in 8.5 min with 0.63 cc voxel size. Fig.1 Non-water-suppressed PEPSI maps on phantom at 7 T show good reconstruction performance for up to 4-fold acceler...

متن کامل

Sources of signal fluctuations in fMRI at 7 Tesla

The development of high-field magnetic resonance imaging (MRI) systems has allowed for critical improvements in image signal-to-noise ratio (SNR), potentially leading to higher sensitivity and spatial resolution for functional MRI (fMRI) techniques. However, recent studies have shown that these potential advantages become significantly compromised by increased signal fluctuations arising from c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008