The Dynamic Behavior of Once-Through Direct Steam Generation Parabolic Trough Solar Collector Row Under Moving Shadow Conditions

نویسندگان

  • Su Guo
  • Yinghao Chu
  • Deyou Liu
  • Xingying Chen
  • Chang Xu
  • Carlos F. M. Coimbra
  • Ling Zhou
  • Qunming Liu
چکیده

Compared with recirculation and injection modes, once-through direct steam generation (DSG) parabolic troughs are simpler to construct and require the lowest investment. However, the heat transfer fluid (HTF) in once-through DSG parabolic trough systems has the most complicated dynamic behavior, particularly during periods of moving shadows caused by small clouds and jet contrails. In this paper, a nonlinear distributed parameter dynamic model (NDPDM) is proposed to model the dynamic behavior of once-through DSG parabolic trough solar collector row under moving shadow conditions. Compared with state-of-the-art models, the proposed NDPDM possesses three characteristics: (a) adopting real-time local values of the heat transfer and friction resistance coefficients, (b) simulating the whole collector row, including the boiler and the superheated sections, and (c) modeling the disturbance of direct normal irradiance (DNI) level on DSG parabolic trough solar collector row under moving shadow conditions. Validated using experimental data, the NDPDM accurately predicts the dynamic characteristics of HTF during periods of partial and moving DNI disturbance. The fundamental and specific dynamic process of fluid parameters for a DSG parabolic trough solar collector row is provided in this paper. The results show the following: (a) Moving shadows have a significant impact on the outlet temperature and mass flow rate, and the impact lasts up to 1000 s even after the shadows completely leave the collector row. (b) The time for outlet steam temperature to reach a steady-state value for the first time is independent of the shadow width, speed, and moving direction. (c) High-frequency chattering of the outlet mass flow rate can be observed under moving DNI disturbance and will have a longer duration if the shadow width is larger or the shadow speed is slower. Compared with cases in which the whole system is shaded, partially shading cases have shown a longer duration of high-frequency chattering. (d) Both wider widths and slower speeds of shadow will cause a larger amplitude of responses in the outlet temperature and mass flow rate. When the shadow speed is low, there is a longer delay time of response in the mass flow rate of the outlet fluid. (e) The amplitude of response in the outlet temperature does not depend on the direction of clouds movement. However, if the DNI disturbance starts at the inlet of the collector row, there will be significant delay times in both outlet temperature and mass flow rate, and a larger amplitude of response in outlet mass flow rate. [DOI: 10.1115/1.4036331]

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Saturated steam process with direct steam generating parabolic troughs

The direct steam generation (DSG) in parabolic trough collectors is an attractive option regarding the economic improvement of parabolic trough technology for solar thermal electricity generation in the multi Megawatt range. The European DISS project has proven the feasibility of the direct steam generation under real solar conditions in more than 4000 operation hours. Within the European R&D p...

متن کامل

Direct Steam Generation in Parabolic Troughs: First Results of the Diss Project

This article presents the latest experimental results of the European DISS (DIrect Solar Steam) project. The experiments are subdivided into steady state and transient tests. The goal of the steady state tests is the investigation of the thermohydraulic phenomena of the occurring two phase flow, whereas the transient tests are needed for the controller design. The experimental results are compa...

متن کامل

Improvements in efficiency of solar parabolic trough

Solar energy is primary source of all type of energy which is present in nature i.e. all the energy derived from it. So, direct utilization of solar energy into useful energy is important. There are so many solar thermal equipments in which concentrating type collector heated the fluid up to 100 to 400C. It is employed for a variety of applications such as power generation, industrial steam gen...

متن کامل

Experimental Investigation on the Effect of Partially Metal Foam inside the Absorber of Parabolic Trough Solar Collector

In the present work the efficiency of a solar parabolic trough has been investigated experimentality. parabolic trough solar collector constitute a proven source of thermal energy for industrial process heat and power genaration. The impact of  using the partially porous media in the absorber on the efficiency of PTC (parabolic trough collector) has been investigated. The porosity of copper foa...

متن کامل

Thermodynamic diagnosis of a novel solar-biomass based multi-generation system including potable water and hydrogen production

In this study, a new proposed multi-generation system as a promising integrated energy conversion system is studied, and its performance is investigated thermodynamically. The system equipped with parabolic trough collectors and biomass combustor to generate electricity, heating and cooling loads, hydrogen and potable water. A double effect absorption chiller to provide cooling demand, a proton...

متن کامل