Report on the Use of Numerical Analysis for Strength Evaluation of Orthopedic Implants

نویسندگان

  • Yoichiro Matsumoto
  • Takashi Yamane
چکیده

For the strength evaluation of orthopedic implants such as hip prostheses, mechanical tests provided in standards such as the Japanese Industrial Standards (JIS), International Organization for Standardization (ISO), and American Society for Testing and Materials (ASTM) are often performed. However, numerical analysis has been increasingly used to identify the worst case before mechanical tests for manufacturing implants with new shapes. In addition, numerical analysis is expected to be used in the future for the prediction of changes in vivo, such as looseness after implantation, and for treatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Current Concepts in Scaffolding for Bone Tissue Engineering

Bone disorders are of significant worry due to their increased prevalence in the median age. Scaffold-based bonetissue engineering holds great promise for the future of osseous defects therapies. Porous composite materials andfunctional coatings for metallic implants have been introduced in next generation of orthopedic medicine for tissueengineering. While osteoconductive materials such as hyd...

متن کامل

Evaluation of Ultimate Torsional Strength of Reinforcement Concrete Beams Using Finite Element Analysis and Artificial Neural Network

Due to lack of theory of elasticity, estimation of ultimate torsional strength of reinforcement concrete beams is a difficult task. Therefore, the finite element methods could be applied for determination of strength of concrete beams. Furthermore, for complicated, highly nonlinear and ambiguous status, artificial neural networks are appropriate tools for prediction of behavior of such states. ...

متن کامل

Rapid Manufacturing of Co-Cr-Mo Implants by Three-Dimentional Printing Process for Orthopedic Applications

     The fabrication of complex-shaped parts out of (wt %) Co-28Cr-6Mo alloy by three-dimensional printing (3DP) was studied using two grades of the alloy with average particle sizes of 20 and 75 μm. To produce sound specimens, 3DP processing parameters were tuned. The sintering behavior of the powders was characterized by the dilatometric analysis. Batch sintering in argon atmosphere at 1280 °...

متن کامل

بررسی نتایج خارج سازی ایمپلنت در بیماران مراجعه کننده به بیمارستان شهید صدوقی یزد از اردیبهشت ماه 1389 لغایت خرداد ماه1394

Introdution: Nowadays, the use of internal fixation in the field of orthopedics is increasing. On the other hand, there is no clear criteria at hand on removal of orthopedic implants, and there is disagreement among orthopedic surgeons on the necessity of routine removal of orthopedic implants in all patients after the healing of the fracture, and many surgeons take a personal approach towards ...

متن کامل

Heat Treatment Of Cobalt-Base Alloy Surgical Implants With Hydroxyapatite-Bioglass For Surface Bioactivation

ASTM F-75 Cobalt-base alloy castings are widely used for manufacturing orthopedic implants. This alloy needs both homogenization and solutionizing heat treatment after casting, as well as bioactivation of the surface to increase the ability of tissue bonding. In this study, ASTM F-75 Cobalt-base substrate was heat treated at 1220°C for 1 hour in contact with Hydroxyapatite-Bioglass powder in or...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016