Sizing and cost estimation methodology for stand-alone residential PV power system
نویسندگان
چکیده
This paper investigates the sizing and costing methodology for a stand-alone photovoltaic (SAPV) power system based on the number of sunshine hours available in the world. The sizing and costing of the PV system for the electrical load of 3.65 kWh/day was presented in this paper for different continents of the world. The unit cost of electricity generated from the PV system was determined based on their life cycle cost analysis. The capital cost and unit cost of electricity for the SAPV systems were evaluated as $9,198/kWp and $0.6/kWh respectively for India. The total CO2 emission mitigated by the PV power system in its lifespan was estimated at 63 tons which correspond to the carbon credits of $2,048.
منابع مشابه
Modeling and sizing optimization of hybrid photovoltaic/wind power generation system
The rapid industrialization and growth of world’s human population have resulted in the unprecedented increase in the demand for energy and in particular electricity. Depletion of fossil fuels and impacts of global warming caused widespread attention using renewable energy sources, especially wind and solar energies. Energy security under varying weather conditions and the corresponding system ...
متن کاملTechno-economic Optimization of a Stand-alone Photovoltaic-battery Renewable Energy System for Low Load Factor Situation- a Comparison between Optimization Algorithms
For remote places having less-strong wind, single resources based renewable energy system (RES) with battery storage can sustainably and economically generate electrical energy. There is hardly any literature on optimal sizing of such RES for very low load demand situation. The objective of this study is to techno-economically optimize the system design of a Photovoltaic (PV)-battery storage RE...
متن کاملOptimization of grid independent diesel-based hybrid system for power generation using improved particle swarm optimization algorithm
The power supply of remote sites and applications at minimal cost and with low emissions is an important issue when discussing future energy concepts. This paper presents modeling and optimization of a photovoltaic (PV)/wind/diesel system with batteries storage for electrification to an off-grid remote area located in Rafsanjan, Iran. For this location, different hybrid systems are studied and ...
متن کاملOptimal Sizing of a Reliable Hydrogen-based Stand-alone Wind-Fuel Cell System
A hybrid wind/ fuel cell generation system is designed to supply power demand. The aim of this design is to minimize the total cost of the hybrid system over an expected 20 years of operation. The optimization problem is solved aimed at providing a reliable supply for the consumer’s demand. The system consists of fuel cells, some wind units, some electrolyzers, a reformer, an anaerobic reactor ...
متن کاملNovel Approach for Optimal Sizing of Stand-alone Hybrid Photovoltaic/Wind Systems
Nowadays using of new energies in the form of dispersed resources in the worlds is wide spreading. In this article we will design a dispersed production source in the form of a solar/wind hybrid power plant in order to supply the energy of a residential unit according to a sample load pattern. The aim of aforementioned design is to reduce its costs in a period of 20 years. In order to optimi...
متن کامل