Radiographically occult right main bronchus intubation with a fastrach laryngeal mask airway endotracheal tube.

نویسندگان

  • Jon S Huseby
  • Steven Legault
چکیده

We report a case in which the distal 3 cm of an LMA-Fastrach laryngeal mask airway (LMA) endotracheal tube (ETT) was radiographically invisible. After the LMA intubation, left lung atelectasis developed. The radiopaque wire coil built into the ETT was mistakenly believed to mark the end of the ETT, so the radiograph made it appear that the end of the ETT was 2 cm above the main carina. In fact, this type of ETT extends 3 cm beyond the end of the wire coil, and the final 3 cm of the ETT can be difficult or impossible to see on a radiograph. Bronchoscopy revealed that the end of the ETT was in the bronchus intermedius. In this case, even in retrospect, the true end of the ETT could not be seen on the radiograph. Clinicians should be aware that the final 3 cm of the LMA-Fastrach ETT can be radiographically invisible. We believe the manufacturer should redesign this ETT to include better radiopaque markers all the way to the end of the ETT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Study to Evaluate Intubation Through Intubating Laryngeal Mask Airway Using Conventional Polyvinyl Chloride Endotracheal Tube

Background: A purposely designed wire reinforced silicone tube is available for tracheal intubation through intubating laryngeal mask airway (ILMA). However, this tube is expensive and not always available. Hence, cheaper and readily available alternatives such as conventional polyvinyl chloride (PVC) endotracheal tube should be evaluated for intubation through ILMA. Methods: After informed con...

متن کامل

A Prospective Randomized Comparative Study on i-gel versus Laryngeal Mask Airway Fastrach as a Conduit for Blind Tracheal Intubation Using Conventional PVC Endotracheal Tubes in Reverse Orientation

Introduction: Laryngeal mask airway (LMA) Fastrach was specially designed as a conduit for blind tracheal intubation in anticipated difficult airway and where we do not require neck extension. i-gel is a disposable, cheap supraglottic device with wide bore stem which facilitates direct passage of a conventional polyvinylchloride (PVC) endotracheal tube. Materials and Methods: A total of 80 adul...

متن کامل

The intubating laryngeal mask airway in failed fibreoptic intubation.

PURPOSE Prediction of difficult tracheal intubation is not always reliable and management with fibreoptic intubation is not always successful. We describe two cases in which blind intubation through the intubating laryngeal mask airway (ILMA FasTrach) succeeded after fibreoptic intubation failed. CLINICAL FEATURES The first patient, a 50 yr old man, was scheduled for elective craniotomy for i...

متن کامل

PREHOSPITAL CARE Securing the prehospital airway: a comparison of laryngeal mask insertion and endotracheal intubation by UK paramedics

Objectives: The recent introduction of a disposable laryngeal mask airway has provided paramedics with an alternative to endotracheal intubation. Time taken to secure the airway with each device was compared in patients undergoing elective surgery. Methods: Patients undergoing general anaesthesia were studied. Paramedics trained in laryngeal mask use and endotracheal intubation participated in ...

متن کامل

Securing the prehospital airway: a comparison of laryngeal mask insertion and endotracheal intubation by UK paramedics.

OBJECTIVES The recent introduction of a disposable laryngeal mask airway has provided paramedics with an alternative to endotracheal intubation. Time taken to secure the airway with each device was compared in patients undergoing elective surgery. METHODS Patients undergoing general anaesthesia were studied. Paramedics trained in laryngeal mask use and endotracheal intubation participated in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 48 5  شماره 

صفحات  -

تاریخ انتشار 2003