Development and Preliminary Validation of Chestband Data from a Full Body Finite Element Model
نویسندگان
چکیده
Post-Mortem Human Subjects (PMHS) and finite element (FE) computer models are often used to examine the biomechanical response of the human body in vehicular crashes. The purpose of this study is to present a methodology for extracting chestband data from a full body FE model, and to compare the model’s results in frontal and lateral impacts to experimental results using chest bands. Chestbands provide chest deformation contours in a given plane during impact. PMHS data from two studies were used to compare chestband data from the Global Human Body Models Consortium (GHBMC) mid-sized male model. The GHBMC model was run using LS-DYNA (LSTC, Livermore, CA, R. 4.2.1) to simulate the impacts from both studies [1, 2]. The model was pre-programmed with an upper, middle, and lower chestband each comprised of 32 nodes. The chestbands were placed around the circumference of the chest approximately at the level of the 4 th , 6 th , and 8 th rib, and matched the description of chestband locations in the literature. The nodal data from the GHBMC model were exported to MATLAB (The Mathworks, R 10). One local coordinate system was defined per chestband using nodes on T9, T12, and L1. Node locations on the chestbands at the maximum deflection state for the GHBMC model were plotted. Maximum deflection was determined using the methods of Kuppa and Eppinger [3]. Additionally, an advantage of the virtual chestband is that it cannot separate from the body since it is composed of nodes on the exterior flesh of the model. When comparing the GHBMC model chestband results to both the frontal impact cases (8.1 meters/second(m/s) and 13.3 m/s) [1], there are strong similarities in shape that are clear functions of the belt path. This includes compression in center of the upper chestband for both cases and for the lower chestband compression is seen on the left side for the 8.1m/s case and on the right side for the 13.3m/s case. Also when comparing the GHBMC model to the lateral impact study [2], the upper and middle chestbands exhibit compression on the left side. For the frontal sled data at 8.1 m/s, the GHBMC model predicted peak deflection of the upper chestband to be 9.7%, where as the literature reported a peak deflection 16±5.6%. For the frontal sled data at 13.3 m/s, the GHBMC model predicted the upper chestband peak deflection to be 11.1%, compared to literature which reported a peak deflection of 23±5.6%. Finally, when examining the lateral sled case, the GHBMC model predicted the percent compression of the upper chestband to be 36.7% and of the middle chestband to be 27.1%, compared to literature which reported a 36.0% and 36.8% compression. Minimal differences between the GHBMC model and lateral case were observed, but somewhat larger discrepancies were observed in frontal thoracic loading. While this work was focused on the technique used to extract chestband data from the model, these initial results will also be used to further validate the GHBMC model.
منابع مشابه
Prediction and optimization of load and torque in ring rolling process through development of artificial neural network and evolutionary algorithms
Developing artificial neural network (ANN), a model to make a correct prediction of required force and torque in ring rolling process is developed for the first time. Moreover, an optimal state of process for specific range of input parameters is obtained using Genetic Algorithm (GA) and Particle Swarm Optimization (PSO) methods. Radii of main roll and mandrel, rotational speed of main roll, pr...
متن کاملEstimation of spinal loads using a detailed finite element model of the L4-L5 lumbar segment derived by medical imaging kinematics; a feasibility study
Introduction: Low back pain is the most prevalent orthopedic disorder and the first main cause of poor working functionality in developed as wells as many developing countries. In Absence of noninvasive in vivo measurement approaches, biomechanical models are used to estimate mechanical loads on human joints during physical activities. To estimate joint loads via musculoskelet...
متن کاملPreliminary results on multi-body dynamic simulation of a new test rig for wheel-rail contact
The ability to perform rolling contact fatigue (RCF) experiments in wheel–rail material is provided by a new small–scale test rig, manifesting the actual dynamic behaviour of the railway system. In this paper, a multi-body dynamics (MBD) model is proposed, simulating the vibration behaviour of the prescribed rig. The new testing facility is modelled using a three-dimensional model of the vehicl...
متن کاملDevelopment of a New Finite Element Model of the Abdomen for Impact
The aim of the current study was to develop a finite element model of the abdomen for impact as part of the GHBMC coordinated effort. The model development and its validation were performed in multiple steps, from the selection of numerical formulations using isolated organ models, to the meshing of the full region and its validation against experimental data. The model response was found to be...
متن کاملEvaluation of Disc Cutter Performance in Rock Cutting Process Using 3D Finite Element Method
Today, numerical simulation can be used as a suitable tool to measure large quantities that are very expensive and, in some cases, impossible to measure. One of the important issues in predicting rock mass boreability in excavation with full face tunnel boring machines is estimating the discchr('39')s forces for rock cutting. For this purpose, the linear cutting test is employed. However, limi...
متن کامل