The effect of attention on conventional automated perimetry and luminance size threshold perimetry.

نویسندگان

  • Michael Wall
  • Kimberly R Woodward
  • Caridad F Brito
چکیده

PURPOSE To investigate the effects of divided attention on conventional automated perimetry (CAP) and luminance size threshold perimetry (LSTP). METHODS Ten healthy subjects, ages 27 to 65, with two perimetry types (CAP and LSTP) were tested in random order. At a later session, these tests were given with a mental workload to simulate the effect of anxiety or distraction on subjects performing visual field testing, also in random order. The mental workload, the Paced Auditory Serial Addition Test (PASAT), was first administered to each subject, and the score was recorded. During the visual field testing, the PASAT was again administered continuously. Each subject was instructed to attend primarily to the PASAT while taking each visual field test. RESULTS CAP was affected by the addition of the PASAT, with a worsening of sensitivity from an average of 30.0 +/- 0.67 to 24.2 +/- 7.4 dB with a range of -0.04 to -23.2 dB (P = 0.04). LSTP showed a generalized reduction in threshold 1.71 +/- 0.22 to 2.35 +/- 0.72 dB with a range of 0.12 to -2.17 dB (P = 0.25). The percentage of correct responses on the PASAT was not significantly different between CAP (76.9%) and LSTP (74.8%). False-positive and -negative catch trial responses were increased during CAP with PASAT testing (P = 0.009). A substantial increase of fixation losses occurred during CAP with PASAT (3.7-16.2, P = 0.002). LSTP with PASAT showed increases in localization error (P < 0.001) and reaction time (P = 0.004). CONCLUSIONS Divided attention significantly affects performance on conventional automated perimetry with its fixed size stimuli and when the stimuli are scaled (LSTP). The deficits may simulate nerve-fiber-bundle-like defects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High spatial resolution automated perimetry in glaucoma.

BACKGROUND Automated perimetry is of fundamental importance in assessing visual function in glaucoma. A technique was evaluated to perform high spatial resolution automated perimetry to allow a more detailed assessment of the luminance sensitivity in selected regions of the visual field than is possible with conventional perimetry. METHOD High spatial resolution perimetry was performed using ...

متن کامل

Comparison between Threshold Pupil Perimetry and Suprathreshold Pupil Perimetry

Purpose: Pupil perimetry has so far been performed by the two following methods: suprathreshold perimetry during which the amplitude or ratio of pupil constriction is determined, and threshold perimetry during which the threshold of pupil reaction is determined. The authors compared the values obtained with these two methods using the modified Octopus 1-2-3. Subjects and methods: Pupil perimetr...

متن کامل

A Comparison of the Effects of Neutral Density Filters and Diffusing Filters on Motion Detection Perimetry, White-on-white Perimetry and Frequency Doubling Perimetry

Background: Motion detection perimetry and frequency doubling perimetry are methods that have been developed with the goal of detecting glaucomatous field defects earlier than conventional white-on-white perimetry. It is well recognized that the development of cataract and pupillary constriction can significantly influence perimetric thresholds when screening for, or following the progression o...

متن کامل

Automated Perimetry Under the Microscope: A Re-Examination of Fundamental Assumptions.

Automated perimetry, a vision test that is likely performed thousands of times a day within the Unites States alone, has been conducted largely unchanged for several decades. It is also true that many of the fundamental parameters of this form of testing were adopted wholesale from manual kinetic perimetry. Research is now emerging, which suggests that many aspects of automated perimetry, from ...

متن کامل

Mechanisms mediating visual detection in static perimetry.

PURPOSE The usual stimuli in static perimetry are white-light luminance increments. However, the specific visual detection mechanisms involved in perimetry are unknown because all classes of neural mechanisms are sensitive to spectrally broadband stimuli. The objective of this study was to determine the relative sensitivities of nonopponent and opponent detecting mechanisms under standard perim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 45 1  شماره 

صفحات  -

تاریخ انتشار 2004