Sheathing of the Endovaginal Ultrasound Probe: Is It Adequate?

نویسندگان

  • Ronald Jimenez
  • Patrick Duff
چکیده

The purpose of this prospective investigation was to compare two methods for sheathing of the endovaginal ultrasound-probe. The study was conducted over a 7-month period in 1991-1992. In the first half of the investigation, latex examination gloves were used to sheath the endovaginal probe; during the second half of the investigation, latex condoms were used. Following the ultrasound examination, the probes were inspected for gross contamination by the ultrasonographer. The sheaths were then tested for perforations by filling them with water to twice their usual volume and observing for leaks. Fifty unused gloves and condoms were similarly tested to determine the prevalence of preexisting defects. One hundred twenty-eight gloves and 102 condoms from patients were tested. Four gloves (3.1%, 95% C.I. 1.6-4.6%) and seven condoms (6.9%, 95% C.I. 4.4-9.4%) had perforations (NS). When the probe was covered by a glove, one instance of visible contamination occurred (0.78%, 95% C.I. 0-1.6%) compared with eight instances when the probe was covered with a condom (7.8%, 95% C.I. 5.2-10.4%, P < .007). The prevalance of preexisting defects in the 50 unused gloves was 2%, which is not significantly different from the prevalence in used gloves. There were no defects in the 50 unused condoms compared with 7 in the used condoms (P = .057). Visible contamination of the endovaginal probe with blood or genital tract secretions is more likely when condoms are used as sheaths. However, even gloves provide imperfect coverage of the probe, illustrating the need for thorough decontamination of the endovaginal instrument after each use.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pnm-1: Applications of Hysterosonography for The Detection of Intracavitary Uterine Abnormalities

Hysterosonography (SHG) is a new noninvasive technique that involves the slow infusion of sterile saline solution into the uterus during ultrasound imaging. Expansion of endometrial cavity by SHG allows optimal visualization and plays an important role in the evaluation of abnormalities related to the uterus. The most common indications for hysterosonography are: abnormal uterine bleeding both ...

متن کامل

Design, Evaluation and Prototyping of a New Robotic Mechanism for Ultrasound Imaging

This paper presents a new robotic mechanism for ultrasound imaging. The device is placed on a patient's body by an operator, and an ultrasound expert controls the motions of the device to obtain ultrasound images. The paper focuses on the robotic mechanism that performs ultrasound imaging. The design of the mechanism is based on two approaches to produce center of motion for an ultrasound probe...

متن کامل

Subchorionic Hemorrhage Appearing as Twin Gestation on Endovaginal Ultrasound

This case study describes a pregnant patient with vaginal bleeding who had a bedside endovaginal ultrasound in the emergency department (ED). The emergency physician identified a live intra-uterine pregnancy (IUP) with another structure that appeared to be a second gestational sac. The patient subsequently had an endovaginal ultrasound in the radiology department 46 minutes later. The attending...

متن کامل

High Risk HPV Contamination of Endocavity Vaginal Ultrasound Probes: An Underestimated Route of Nosocomial Infection?

BACKGROUND Endocavity ultrasound is seen as a harmless procedure and has become a common gynaecological procedure. However without correct disinfection, it may result in nosocomial transmission of genito-urinary pathogens, such as high-risk Human Papillomavirus (HR-HPV). We aimed to evaluate the currently recommended disinfection procedure for covered endocavity ultrasound probes, which consist...

متن کامل

Difference between efficiency of ultrasound treatments above and below the membrane surface in membrane clarification of pomegranate juice

Microfiltration can clarify pomegranate juice; however, fouling is a limiting phenomenon in the process. In current work ultrasound was applied above and below the membrane surface to reduce fouling after removing temperature effect. A hydrophilic mixed cellulose ester membrane with pore size of 0.45 μm was used in lab scale flat sheet module. Membrane module was placed above and below the ultr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Infectious Diseases in Obstetrics and Gynecology

دوره 1  شماره 

صفحات  -

تاریخ انتشار 1993