End-tidal CO2 for prediction of cardiac output following weaning from cardiopulmonary bypass.

نویسندگان

  • Anis S Baraka
  • Marie T Aouad
  • Maya I Jalbout
  • Roland N Kaddoum
  • Mohammad F Khatib
  • Sania T Haroun-Bizri
چکیده

This prospective study included 32 patients undergoing cardiopulmonary bypass (CPB) for elective coronary artery bypass grafting correlates the respiratory end-tidal CO2 (ETCO2) during partial separation from CPB with cardiac output (CO) following weaning from CPB. After induction of general anesthesia, a pulmonary artery catheter was inserted for measurement of cardiac output by thermodilution. Patients were monitored using a 5-lead ECG, pulse oximeter, invasive blood pressure monitoring, rectal temperature probe, and end-tidal capnography. At the end of surgery, patients were weaned from CPB in a stepwise fashion. Respiratory ETCO2 and in-line venous oximetry were continuously monitored during weaning. The ETCO2 was recorded at quarter pump flow and after complete weaning from CPB. Following weaning from CPB, CO was measured by thermodilution. The CO values were correlated with the ETCO2 during partial bypass and following weaning from bypass. Regression analysis of ETCO2 at quarter-flow and post-bypass CO showed significant correlation (r = 0.57, p < .001). Also, regression analysis of ETCO2 after complete weaning from bypass and post-bypass CO showed significant correlation (r = 0.6, p = .002). The correlation between ETCO2 and CO showed that an ETCO2 >30 mm Hg during partial CPB will always predict an adequate CO following weaning from CPB. An ETCO2 <30 mm Hg may denote either a low or a normal cardiac output and hence other predictive parameters such as SvO2 must be added.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measuremient of end-tidal carbon dioxide concentration during cardiopulmonary resuscitation

End-tidal carbon dioxide concentrations were measured prospectively in 12 cardiac arrest patients undergoing cardiopulmonary resuscitation (CPR) in an accident and emergency department. The end-tidal carbon dioxide (CO2) concentration decreased from a mean (+ SD) of 4-55 + 0.88% 1 min after chest compression and ventilation was established, to values ranging from 2-29 + 0-84% at 2min to 1-56 + ...

متن کامل

Measurement of end-tidal carbon dioxide concentration during cardiopulmonary resuscitation.

End-tidal carbon dioxide concentrations were measured prospectively in 12 cardiac arrest patients undergoing cardiopulmonary resuscitation (CPR) in an accident and emergency department. The end-tidal carbon dioxide (CO2) concentration decreased from a mean (+/- SD) of 4.55 +/- 0.88% 1 min after chest compression and ventilation was established, to values ranging from 2.29 +/- 0.84% at 2 min to ...

متن کامل

End-tidal carbon dioxide monitoring in pediatric emergencies.

End-tidal carbon dioxide (CO2) monitoring is useful in the prehospital setting, emergency department, intensive care unit, and operating room. Capnography provides valuable, timely information about the function of both the cardiovascular and respiratory systems. End-tidal CO2 monitoring is the single most useful method in confirming endotracheal tube position. It also provides information abou...

متن کامل

Post Hoc analysis of cardiopulmonary indicators trends among post-operative coronary artery bypass graft patients with normal ventilator weaning response and dysfunctional ventilator weaning response

Objectives: The objectives of this post hoc analysis was to describe the characteristics of cardiopulmonary indicators among patients with normal ventilator weaning response and dysfunctional ventilator weaning response after coronary artery bypass graft surgery, and to find the differences in characteristics of cardiopulmonary indicators between patients with normal ventilator weaning response...

متن کامل

Prediction of post-cardiopulmonary bypass cardiac output by venous oximetry.

The present study evaluates two equations for predicting the post-cardiopulmonary bypass cardiac output (CO) in 10 patients undergoing coronary artery bypass grafting. One equation is based on the relationship of CO with mixed venous oxygen saturation (SVO 2), while the second equation is based on the relationship with oxygen extraction (1 - SVO 2). Each patient served as his own control. Du...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 36 3  شماره 

صفحات  -

تاریخ انتشار 2004