Confirming placement of nasogastric feeding tubes.

نویسندگان

  • Marie-Andrée Lortie
  • Emmanuel Charbonney
چکیده

A 78-year-old alert woman in hospital was being fed through a nasogastric tube because of deconditioning. She was taking acetylsalicylic acid for ischemic cardiomyopathy, and a vitamin K antagonist for atrial fibrillation and a recent axillobifemoral bypass thrombosis. She had a permanent right-side nephrostomy after receiving an injury to the ureter during the bypass surgery. She did not have swallowing deficits or any neurologic impairment, but her caloric intakes were insufficient. The nasogastric tube malfunctioned and was replaced with a new one, using a metal guide wire; the patient coughed briefly during the replacement procedure. Afterwards, she reported high lumbar and retrothoracic pain on the right side, just above the nephrostomy. A control chest radiograph, ordered by the treating physician, showed that the feeding tube had been incorrectly placed into the posterior pleural space and had passed through the right bronchus and lower lobe of the lung (Figure 1A). No feeding had been started and no hemoptysis was present. Removal of the feeding tube led to a pneumothorax, which was drained (Figures 1B, 1C). The patient was monitored in the intensive care unit for 24 hours, without further complications. Incorrect placement of nasogastric tubes can lead to numerous complications, including bronchopleural fistula, pneumothorax and aspiration pneumonia.1 Other lesions of the nasopharyngeal, laryngeal, esophageal and airway structures may occur; however, the structure of the lung parenchyma is more prone to perforation. Patients with suppressed cough or gag reflexes, or with impaired consciousness (e.g., critically ill patients) are at highest risk for incorrect placement of the nasogastric tube. Chest radiography is the gold standard for confirming appropriate placement of a nasogastric tube. If the feeding tube is blindly inserted, radiographic confirmation of correct placement is recommended before administration of medication or feeding.2 There should be no exceptions to this rule, because other methods (e.g., auscultation of air blow, examination of gastric aspirate and measurement of its pH) are unreliable.3

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Competence in confirming correct placement of nasogastric feeding tubes amongst FY1 doctors

Foundation year one (FY1) doctors are required to confirm correct placement of nasogastric (NG) feeding tubes on chest radiography on a regular basis. Many FY1s do not receive formal training during medical school or during the FY1 year. Multiple incidents of harm to patients, including death, resulting from incorrect placement of an NG feeding tube have been reported to the National Patient Sa...

متن کامل

Confirming nasogastric tube position: methods & restrictions: A narrative review

Background and Purpose: Inserting a nasogastric tube, though a common clinical procedure with widespread use for critically ill patients, can produce unexpected complications so that tube misplacement into the lungs is a potential complication with serious consequences. The reliability of common bedside methods to differentiate between pulmonary and gastric placement has not been acceptable. Th...

متن کامل

Blindly inserted nasogastric feeding tubes and thoracic complications in intensive care

Purpose of review: This article reviews the thoracic complications from malpositioned blindly inserted nasogastric feeding tubes in mechanically ventilated patients in intensive care and the methods to check the position and promote safe placement of the feeding tubes. Recent findings: Malpositioned feeding tubes are not included in risk management databases. The reported incidence is 1-3% and ...

متن کامل

Changing how we confirm ngt placement: impact on nutrition delivered

Introduction Confirming the position of Nasogastric tubes (NGT) in critical care is a controversial area. The National Patient Safety Agency (NPSA) guidance [1] advocates pH testing although use is limited in ICU due to continuous enteral feeding and proton pump inhibitor therapy. Chest X-ray is therefore commonly used with trainee doctors often being responsible for confirming tube position. F...

متن کامل

Comparison of using cooled and regular-temperature nasogastric tubes on the success of nasogastric intubation

Background: Successful nasogastric intubation is defined as “correct placement of the tube with minimum number of attempts” which is an important issue in nasogastric intubation. Due to controversies in the use of cold tubes in nasogastric tube insertion, need for research in this area seems necessary. Aim: To compare the effect of using cold versus regular-temperature nasogastric tubes on succ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • CMAJ : Canadian Medical Association journal = journal de l'Association medicale canadienne

دوره 188 5  شماره 

صفحات  -

تاریخ انتشار 2016