The H-ARS Dose Response Relationship (DRR): Validation and Variables.

نویسندگان

  • P Artur Plett
  • Carol H Sampson
  • Hui Lin Chua
  • William Jackson
  • Sasidhar Vemula
  • Rajendran Sellamuthu
  • Alexa Fisher
  • Hailin Feng
  • Tong Wu
  • Thomas J MacVittie
  • Christie M Orschell
چکیده

Manipulations of lethally-irradiated animals, such as for administration of pharmaceuticals, blood sampling, or other laboratory procedures, have the potential to induce stress effects that may negatively affect morbidity and mortality. To investigate this in a murine model of the hematopoietic acute radiation syndrome, 20 individual survival efficacy studies were grouped based on the severity of the administration (Admn) schedules of their medical countermeasure (MCM) into Admn 1 (no injections), Admn 2 (1-3 injections), or Admn 3 (29 injections or 6-9 oral gavages). Radiation doses ranged from LD30/30 to LD95/30. Thirty-day survival of vehicle controls in each group was used to construct radiation dose lethality response relationship (DRR) probit plots, which were compared statistically to the original DRR from which all LDXX/30 for the studies were obtained. The slope of the Admn 3 probit was found to be significantly steeper (5.190) than that of the original DRR (2.842) or Admn 2 (2.009), which were not significantly different. The LD50/30 for Admn 3 (8.43 Gy) was less than that of the original DRR (8.53 Gy, p < 0.050), whereas the LD50/30 of other groups were similar. Kaplan-Meier survival curves showed significantly worse survival of Admn 3 mice compared to the three other groups (p = 0.007). Taken together, these results show that stressful administration schedules of MCM can negatively impact survival and that dosing regimens should be considered when constructing DRR to use in survival studies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Validation Study on Radiation properties of a Novel LiF: Mg, Ti Known as IAP-100

Introduction: LiF dosimeter has the most application in medicine. This study aimed to evaluate some dosimetric properties of a novel LiF: Mg, Ti. Materials and Methods: An ELEKTA Precise linear accelerator was used to calibrate dosimeters at 6 MV. In this survey, responses of dosimeters were evaluated up to 1000 cGy. Background effect was investigated in two different dosimeter states includin...

متن کامل

Durable response rate as an endpoint in cancer immunotherapy: insights from oncolytic virus clinical trials

BACKGROUND Traditional response criteria may be insufficient to characterize full clinical benefits of anticancer immunotherapies. Consequently, endpoints such as durable response rate (DRR; a continuous response [complete or partial objective response] beginning within 12 months of treatment and lasting ≥6 months) have been employed. There has not, however, been validation that DRR correlates ...

متن کامل

Determination of geometric accuracy of radiotherapy fields by port film and DRR using Matlab Graphical User Interface

Introduction: Radiation therapy is one of the methods of cancer treatment. In this method, it is necessary to avoid harming the healthy tissues of the patient which is in the vicinity of the target, as much as possible. Treatment verification is one of the most important steps of radiation therapy which has two usual methods, using Port film and EPID. The accuracy and precision of treatment in ...

متن کامل

Determination of dose-response relationship in cultured human lymphocytes for biological dosimetry

Background: Lymphocyte-dicentric assay is the most generally accepted method for biological dosimetry of overexposed individuals. In this study, the frequency of unstable chromosome aberration in blood lymphocytes was used to estimate radiation dose received by individuals. Evaluation of dose using a calibration curve produced elsewhere may have a significant uncertainty therefore, experiments ...

متن کامل

Markers of airway inflammation and airway hyperresponsiveness in patients with well-controlled asthma.

In steroid-naive asthmatics, airway hyperresponsiveness correlates with noninvasive markers of airway inflammation. Whether this is also true in steroid-treated asthmatics, is unknown. In 31 stable asthmatics (mean age 45.4 yrs, range 22-69; 17 females) taking a median dose of 1,000 microg inhaled corticosteroids (ICS) per day (range 100-3,600 microg x day(-1)), airway responsiveness to the "di...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Health physics

دوره 109 5  شماره 

صفحات  -

تاریخ انتشار 2015