Failure of disposable domes to prevent septicemia acquired from contaminated pressure transducers.
نویسندگان
چکیده
Between January and June 1976, eight cases of primary bacteremia due to Enterobacter cloacae occurred in patients after open-heart surgery in a hospital in Connecticut. Epidemiologic studies implicated radial arterial catheters as the route of acquistion of E cloacae, and bacteriologic studies confirmed arterial pressure transducers as the sources of bacteria. Prospective studies indicated that the disposable domes from the pressure transducers did not prevent the spread of bacteria from contaminated transducers to the arterial catheters. This is the first report of transducer-acquired bacteremic infections occurring with the use of disposable domes. Although disposable domes may decrease the chances of cross-contamination of circuits for monitoring pressure, they do not, as previously thought, eliminate the risk of bacteremia from this source.
منابع مشابه
Community Versus Nosocomial Staphylococcus aureus Septicemia in Children Admitted to Aliasghar Children Hospital, Tehran, Iran
Background and Objectives: The aim of the study was to determine the role and characteristics of nosocomial and community acquired Staphylococcus sepsis in admitted children in tertiary centers in Iran. Patients and Methods: A cross sectional descriptive-analytic study was performed since March 2008 to March 2009 in which all blood cultures from various admitted patients were checked for Sta...
متن کاملPatient shoe covers: Transferring bacteria from the floor onto surgical bedsheets.
Forty disposable medical shoe covers were briefly exposed to the surgical floor and were found contaminated by a large number of bacteria. This study also demonstrated live bacteria, including pathogens attached to contaminated shoe covers, can be subsequently transferred to surgical bedsheets. We suggest an infection control policy should be considered to prevent patients returning to their be...
متن کاملImpact Analysis of Variation in Geometrical Features on Intrinsic Characteristics of Capacitive Micro-machined Ultrasonic Transducers
Capacitive Micro-machined Ultrasonic Transducers (CMUTs) are the ultrasonic devices which produce better features in contrast to piezoelectric transducers. The intrinsic parameter of CMUT varies with the variation in geometrical dimension of the device. The cavity height and the radius of the CMUT with circular membrane is varied in the lumped parallel plate model for its impact on the paramete...
متن کاملPrevalence of Microorganisms Causing Septicemia and Determination of Antimicrobial Resistance in Intensive Care Unit
The objective of this study was to determine the frequency of microorganisms isolated from blood samples of patients admitted to Intensive Care Unit (ICU), and the rate of their resistance to common administered antibiotics in an Iranian ICU. One-hundred patients with Systemic Inflammatory Response Syndromes (SIRS), hospitalized in ICU of Sina Hospital, Tehran, Iran, were entered to this cross-...
متن کاملPrevalence of Microorganisms Causing Septicemia and Determination of Antimicrobial Resistance in Intensive Care Unit
The objective of this study was to determine the frequency of microorganisms isolated from blood samples of patients admitted to Intensive Care Unit (ICU), and the rate of their resistance to common administered antibiotics in an Iranian ICU. One-hundred patients with Systemic Inflammatory Response Syndromes (SIRS), hospitalized in ICU of Sina Hospital, Tehran, Iran, were entered to this cross-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 74 5 شماره
صفحات -
تاریخ انتشار 1978