Future trends in aberration-corrected electron microscopy.

نویسنده

  • Harald H Rose
چکیده

The attainable specimen resolution is determined by the instrumental resolution limit d(i) and by radiation damage. Solid objects such as metals are primarily damaged by atom displacement resulting from knock-on collisions of the incident electrons with the atomic nuclei. The instrumental resolution improves appreciably by means of aberration correction. To achieve atomic resolution at voltages below approximately 100 kV and a large number of equally resolved image points, we propose an achromatic electron-optical aplanat, which is free of chromatic aberration, spherical aberration and total off-axial coma. Its anisotropic component is eliminated either by a dual objective lens consisting of two separate windings with opposite directions of their currents or by skew octopoles employed in the TEAM corrector. We obtain optimum imaging conditions by operating the aberration-corrected electron microscope at voltages below the knock-on threshold for atom displacement and by shifting the phase of the non-scattered wave by pi/2 or that of the scattered wave by -pi/2. In this negative contrast mode, the phase contrast and the scattering contrast add up with the same sign. The realization of a low-voltage aberration-corrected phase transmission electron microscope for the visualization of radiation-sensitive objects is the aim of the proposed SALVE (Sub-A Low-Voltage Electron microscope) project. This microscope will employ a coma-free objective lens, an obstruction-free phase plate and a novel corrector compensating for the spherical and chromatic aberrations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New possibilities with aberration-corrected electron microscopy.

Unlike light microscopy, where resolution is diffraction limited, the achievable resolution of electron microscopes is limited by lens aberrations so severe that the practical resolution is orders of magnitude worse than the diffraction limit. About 10 years ago, the first practical electron lens spherical aberration correctors were developed, and in the past decade, their performance, versatil...

متن کامل

Experimental setup for energy-filtered scanning confocal electron microscopy (EFSCEM) in a double aberration-corrected transmission electron microscope

Scanning confocal electron microscopy (SCEM) is a new imaging mode in electron microscopy. Spherical aberration corrected electron microscope instruments fitted with two aberration correctors can be used in this mode which provides improved depth resolution and selectivity compared to optical sectioning in a conventional scanning transmission geometry. In this article, we consider a confocal op...

متن کامل

Aberration Corrected Electron Microscopy: Prospects and Applications

Aberration correction in the TEM is now relatively well established with more than 20 corrected instruments installed worldwide. This paper will review these instrumental advances and will also describe the underlying theory and computation required to optimise data acquisition and interpret aberration corrected images. Finally the combination of direct electron optical correction and indirect ...

متن کامل

Current and future aberration correctors for the improvement of resolution in electron microscopy.

The achievable resolution of a modern transmission electron microscope (TEM) is mainly limited by the inherent aberrations of the objective lens. Hence, one major goal over the past decade has been the development of aberration correctors to compensate the spherical aberration. Such a correction system is now available and it is possible to improve the resolution with this corrector. When high ...

متن کامل

Chromatic Confocal Electron Microscopy with a Finite Pinhole Size

Scanning confocal electron microscopy (SCEM) is a new imaging mode in electron microscopy. Spherical aberration corrected electron microscope instruments fitted with two aberration correctors can be used in this mode which provides improved depth resolution and selectivity compared to optical sectioning in a conventional scanning transmission geometry. In this article, we consider the depth res...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Philosophical transactions. Series A, Mathematical, physical, and engineering sciences

دوره 367 1903  شماره 

صفحات  -

تاریخ انتشار 2009