ICP OES Determination of Contaminant Elements Leached from Food Packaging Films
نویسندگان
چکیده
Determination of potential contaminants elements in food packing films arising from contact with acidic aqueous foods was undertaken by inductively coupled plasma optical emission spectrometry (ICP OES) in accordance with DIN EN 1186-1. Test sections from plastic films were totally immersed in 3% w/v CH3COOH used as the food simulant. Testing was conducted under three conditions: (1) 10 days at 40 oC; (2) 30 min at 70 oC and 10 days at 40 oC; and (3) 30 min at 100 oC and 10 days at 40 oC. These time and temperature conditions were considered to be the most severe situations likely to be encountered in practice. Several different containers were investigated, including a borosilicate glass beaker, a glass bottle used for food canning, as well as one of polystyrene. The glass bottle was selected for testing treatments according to procedure (3) and a polystyrene one was chosen for use with procedures (1) and (2). Limits of quantitation were adequate for the determination of Ag, B, Ba, Cd, Cr, Cu, Pb, Sb, Sn and Zn by solution nebulization ICP OES and As by chemical vapor generation (CVG-ICP OES). Results for the analysis of AccuStandard certified reference materials as well as spike recoveries show good agreement with expected concentrations, demonstrating the accuracy and precision of the determinations. Eleven samples of food packing material were analyzed. The lead was present in the range 4.8 85.3 μg L in 10 of 11 evaluated packing material, showing the importance of quality control measures.
منابع مشابه
Presence of nonylphenols in plastic films and their migration into food simulants.
Nonylphenols (NP) possess estrogenic activities and may cause increased risk of cancerous and reproductive abnormalities in several living organisms. Despite their harmful nature, NPs are used as additives in food packaging material, especially plastic, which is the main food contact material in today's packaging landscape. According to the fact that food packaging is one of the major potential...
متن کاملHigh precision measurement of silicon in naphthas by ICP-OES using isooctane as diluent.
An analytical protocol for the accurate and precise determination of Si in naphthas is presented by using ICP-OES, optimizing from the sample preparation to the measurement conditions, in order to be able to analyze for the first time silicon contents below 100µgkg-1 in a relatively short time thus being used as a control method. In the petrochemical industry, silicon can be present as a contam...
متن کاملEvaluation of the Migration of Antimony from Polyethylene Terephthalate (PET) Plastic Used for Verjuice and Lemon Juice Packaging
The migration of antimony (Sb) from polyethylene terephthalate (PET) bottling for acidic juices have been assessed in this study. Inductively coupled plasma mass spectrometric (ICP-MS) method was chosen for antimony content determination. Experiments were undertaken at different conditions (15, 25, 35, 45days at 25, 50°C for first use bottle, reused bottle). Two different acidic juices (lemon j...
متن کاملLinear and Nonlinear Multivariate Classification of Iranian Bottled Mineral Waters According to Their Elemental Content Determined by ICP-OES
The combinations of inductively coupled plasma-optical emission spectrometry (ICP-OES) and three classification algorithms, i.e., partial least squares discriminant analysis (PLS-DA), least squares support vector machine (LS-SVM) and soft independent modeling of class analogies (SIMCA), for discriminating different brands of Iranian bottled mineral waters, were explored. ICP-OES was used for th...
متن کاملSingle-element solution comparisons with a high-performance inductively coupled plasma optical emission spectrometric method.
A solution-based inductively coupled plasma optical emission spectrometric (ICP-OES) method is described for elemental analysis with relative expanded uncertainties on the order of 0.1% relative. The single-element determinations of 64 different elements are presented, with aggregate performance results for the method and parameters for the determination of each element. The performance observe...
متن کامل