A pulsed Doppler echocardiographic method for calculation of pulmonary and systemic flow: accuracy in a canine model with ventricular septal defect.

نویسندگان

  • L M Valdes-Cruz
  • S Horowitz
  • E Mesel
  • D J Sahn
  • D C Fisher
  • D Larson
  • S J Goldberg
  • H D Allen
چکیده

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A pulsed Doppler echocardiographic method for calculating pulmonary and systemic blood flow in atrial level shunts: validation studies in animals and initial human experience.

The purpose of this study was to assess the accuracy of a quantitative two-dimensional range-gated Doppler echocardiographic method for estimating systemic and pulmonary flows in an open-chest canine preparation with a variable-sized atrial level shunt mimicking an atrial septal defect. In addition, we also report our initial experience with 10 children who had isolated atrial septal defects an...

متن کامل

Normal pulsed wave Doppler echocardiographic parameters of Turkmen horses of Iran

Turkmen horse is one of the oldest and purest breeds in the world, but there is no information on Doppler echocardiographic parameters in this horse. In the present study, pulsed-wave (PW) Doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing Turkmen horses. No cardiac disease was detected with two-dimensional (2-D) real-time, M-mode, and colour flow mapping. D...

متن کامل

Noninvasive pulsed Doppler echocardiographic detection of the direction of shunt flow in patients with atrial septal defect: usefulness of the right parasternal approach.

Noninvasive pulsed Doppler echocardiography combined with two-dimensional echocardiography by the right parasternal approach was performed to detect the shunt flow through the defect in 31 patients with suspected secundum atrial septal defect (ASD). A defect of the interatrial septum was seen on the two-dimensional echocardiograms of 30 of 31 patients. In all the 30 patients, Doppler signals of...

متن کامل

Diagnosis of ventricular septal defect by pulsed Doppler echocardiography. Sensitivity, specificity and limitations.

The M-mode echocardiographic findings of ventricular septal defect (VSD) are nonspecific. A specific pulsed Doppler echocardiographic (PDE) diagnosis of VSD can be made by following the turbulent VSD jet through the septum. To assess the sensitivity, specificity and limitations of PDE diagnosis of VSD, 105 children undergoing cardiac catheterization were examined by PDE. These children had a va...

متن کامل

Integrated Percutaneous Atrial Septal Defect Occlusion and Pulmonary Balloon Valvuloplasty

Introduction: Atrial Septal Defect (ASD) is one of the most common congenital heart diseases during childhood. Today, ASD closure is done by occlutech device via cardiac catheterization. ASD repair with transcatheter technique has shown high closure rate. However, coexistence of severe pulmonary stenosis and large defect in atrial septum is rare. When these two problems coexist, the result is i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 68 3  شماره 

صفحات  -

تاریخ انتشار 1983