Tibial Base Plate for Total Knee Arthroplasty: Symmetric or Asymmetric?

نویسندگان

  • Murat Bozkurt
  • Mustafa Akkaya
  • Mesut Tahta
  • Safa Gursoy
  • Ahmet Firat
چکیده

BACKGROUND Ideal positioning and best coverage of the tibial base plate are essential in total knee arthroplasty. There are 2 types of tibial base plates: symmetric and asymmetric. The superiority of one to the other is still controversial. The aim of this study was to compare symmetric and asymmetric tibial base plates for total knee arthroplasty in terms of rotational alignment and coverage. METHODS The study was conducted on a total of 80 cadaveric tibial bones. Two surgeons were asked to place 20 symmetric (group 1) and 20 asymmetric (group 2) tibial base plates taking care to ensure the best coverage that they were able to determine. Afterwards, the rotational errors and coverage were assessed with reference to the posterior tibial margin and posterior condylar axis on the three-dimensional computed tomography (3D CT) scan. In the second part of the study, the surgeons were asked to place 20 symmetric (group 3) and 20 asymmetric (group 4) base plates taking care to ensure the best rotational alignment. The rotational errors and the areas uncovered or overstuffed after the application were measured on the 3D CT scan. RESULTS On the comparison of rotational errors, while there was no significant difference between group 1 and group 2 in terms of coverage (p = 0.624), the mean external rotation error was significantly greater in group 2 (p = 0.034). On the comparison of coverage, while there was no significant difference between group 3 and group 4 in terms of rotation (p = 0.36), the mean ratios of the uncovered tibial surface to the total tibial surface (p = 0.041) and also the overstuffed area to the total base plate surface (p = 0.029) were significantly greater in group 4. CONCLUSIONS The determination of correct size and rotation of the tibial component is essential for favorable outcomes of total knee arthroplasty. In this study, the symmetric tibial base plate design was more effective than the asymmetric design in providing the ideal tibial rotation and coverage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Combined Rotational Alignment Change after Total Knee Arthroplasty in Different Tibial Component Designs: Implications for Optimal Tibial Component Rotational Alignment

Purpose The rotational alignment of the femoral and tibial components is closely related to the results after total knee arthroplasty (TKA). In this study, we measured the combined rotational alignment change (ΔCR) after TKA and compared the different influence of symmetric and asymmetric tibial component designs on the combined rotational alignment. Materials and Methods Eighty-four patients...

متن کامل

Acute Primary Total Knee Arthroplasty for Proximal Tibial Fractures in Elderly

Background: Proximal tibial fractures in elderly patients with osteoporosis or knee osteoarthritis (OA) are challengingcases. In the current study, we present our experience with uncommon acute primary total knee arthroplasty (PTKA)in this patient population.Methods: PTKAs were performed following proximal tibial fractures in 30 consecutive patients over 60 years of agewith osteoporosis or knee...

متن کامل

Does a Previous High Tibial Osteotomy (HTO) Influence the Long-term Function or Survival of a Total Knee Arthroplasty (TKA)?

 High tibial osteotomy (HTO) is a well established technique for the treatment of medial osteoarthritis ofthe knee with varus malalignment. The outcome of total knee arthroplasty (TKA) after HTO remains uncertain.The aim of this paper is to revise the literature with the aim of answering the following question: Does a previous (HTO)influence the long-term function or survival of a TKA?. The sea...

متن کامل

Unicompartmental Knee Osteoarthritis (UKOA): Unicompartmental Knee Arthroplasty (UKA) or High Tibial Osteotomy (HTO)?

  Background: The aim of this review article is to analyze the results of high tibial osteotomy compared to unicompartmental knee arthroplasty in patients with unicompartmental knee osteoarthritis.   Methods: The search engine used was PubMed. The keywords were: "high tibial osteotomy versus unicompartmental knee arthroplasty". Twenty-one articles were found on 28 February 2015, but only eighte...

متن کامل

Comparison of tibial bone coverage of 6 knee prostheses: a magnetic resonance imaging study with controlled rotation.

PURPOSE To compare the extent of tibial bone covered by the tibial tray in 6 most commonly used total knee arthroplasty designs in order to strike a balance between mediolateral cortical fit and optimal tibial component rotation. METHODS In 74 men and 27 women aged 17 to 60 (mean, 32) years with suspected soft-tissue injuries, their magnetic resonance images of the knee in full extension were...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2017