Biomechanical evaluation of metacarpal fracture fixation: application of a 90° internal fixation model.
نویسندگان
چکیده
PURPOSE Complications in metacarpal fracture treatment increase in proportion to the severity of the initial injury and the invasiveness of the surgical fixation technique. This manuscript evaluates the feasibility of minimizing internal fixation construct size and soft tissue dissection, while preserving the advantages of stable internal fixation in a biomechanical model. We hypothesized that comparable construct stability could be achieved with mini-plates in an orthogonal (90/90) configuration compared with a standard dorsal plating technique. METHODS This hypothesis was evaluated in a transverse metacarpal fracture model. Twelve metacarpals were subject to either placement of a 2.0-mm six-hole dorsal plate or two 1.5-mm four-hole mini-plates in a 90/90 configuration. These constructs were tested to failure in a three-point bending apparatus, attaining failure force, displacement, and stiffness. RESULTS Mean failure force was 353.5 ± 121.1 N for the dorsal plating construct and 358.8 ± 77.1 N for the orthogonal construct. Mean failure displacement was 3.3 ± 1.2 mm for the dorsal plating construct and 4.1 ± 0.9 mm for the orthogonal construct. Mean stiffness was 161.3 ± 50.0 N/mm for the dorsal plating construct and 122.1 ± 46.6 N/mm for the orthogonal construct. Mean failure moment was 3.09 ± 1.06 Nm for the dorsal plating construct and 3.14 ± 0.67 Nm for the orthogonal construct. The dorsal plating group failed via screw pullout, whereas the orthogonal failed either by screw pullout or breakage of the plate. CONCLUSIONS When subject to apex dorsal bending, the orthogonal construct and the standard dorsal plate construct behaved comparably. These data suggest that despite its shorter length, lower profile, and less substantial screws, the orthogonal construct provides sufficient rigidity. CLINICAL RELEVANCE This study represents a "proof of concept" regarding the applicability of orthogonal plating in the metacarpal and provides the foundation for minimizing construct size and profile.
منابع مشابه
RESPONSE OF METACARPAL FRACTURE FIXATION CONSTRUCTS TO PHYSIOLOGICAL LOADINGS
This study compares the functional capabilities of different metacarpal fixation constructs under physiological loadings in an attempt to identify the optimal construct rather than the strongest one. One hundred and twenty-six preserved human metacarpals were mechanically tested after oblique osteotomies and internal fixation. Maximum load to failure, average structural rigidity, and energ...
متن کاملMECHANICAL EVALUATION OF ALUMINUM OXIDE ROUGHENED SCREWS IN EQUINE THIRD METACARPAL BONE A Thesis
................................................................................................................................. vii CHAPTER 1 GENERAL INTRODUCTION ............................................................ 1 1.1 General Principles of Equine Fracture Repair........................................................ 2 1.2 Bone Structure and Function. Bone Healing....................
متن کاملStandard bicortical screw fixation is not superior to monocortical fixation using mini-locking plates: a biomechanical study in a metacarpal fracture model
Standard bicortical screw fixation is not superior to monocortical fixation using mini-locking plates: a biomechanical study in a metacarpal fracture model Sabine Ochman1, Stefanie Doht2, Juergen Paletta3, Martin Langer1, Michael J. Raschke1, Rainer H. Meffert1 1Trauma, Hand and Reconstructive Surgery, University of Muenster, Muenster, Germany; 2Trauma-, Hand-, Plasticand Reconstructive Surgery...
متن کاملStability of Unicortical versus Bicortical Metacarpal Fracture Internal Fixation Trial (SUBMIT): study protocol for a randomized controlled trial
BACKGROUND Metacarpal fractures are common, accounting for 40 % of all hand injuries. The use of plates for the fixation of these fractures allows early aggressive hand therapy post-operatively, reducing post-operative stiffness. Traditionally, bicortical fixation is the standard practice, where both dorsal and palmar cortices of the metacarpal are drilled through, with screws engaging both cor...
متن کاملBiomechanical Analysis of the Efficacy of Locking Plates during Cyclic Loading in Metacarpal Fractures
PURPOSE To analyse the biomechanical characteristics of locking plates under cyclic loading compared to a nonlocking plate in a diaphyseal metacarpal fracture. METHODS Oblique diaphyseal shaft fractures in porcine metacarpal bones were created in a biomechanical fracture model. An anatomical reduction and stabilization with a nonlocking and a comparable locking plate in mono- or bicortical sc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Hand
دوره 10 1 شماره
صفحات -
تاریخ انتشار 2015