An evaluation of infra-red tympanic thermometry for thermal physiology research.
نویسنده
چکیده
This study forms part of a research programme to investigate the relationships between the rise in core temperature and the environmental temperature in soldiers exercising at a constant rate. The measurement of core temperature is a fundamental requirement for this research. The aim of this study was to evaluate the use of an infra-red tympanic thermometer (IVAC Corecheck) for use in thermal physiological studies conducted outside the laboratory environment by comparing the right ear temperature by TM thermometer and the left ear external auditory meatus by thermistor. The slope of the regression line between the two measurements was 0.9967 with a correlation coefficient of 0.706 which is reasonable. The TM thermometer in general reads higher than the aural thermometer with a 95% confidence limit for agreement from +0.78 to -0.53 degrees C of the aural temperature. Thus this study demonstrated that the tympanic thermometer (IVAC Corecheck) is sufficiently reliable compared to the aural thermistor to justify field trials.
منابع مشابه
Infra-red thermometry: the reliability of tympanic and temporal artery readings for predicting brain temperature after severe traumatic brain injury
INTRODUCTION Temperature measurement is important during routine neurocritical care especially as differences between brain and systemic temperatures have been observed. The purpose of the study was to determine if infra-red temporal artery thermometry provides a better estimate of brain temperature than tympanic membrane temperature for patients with severe traumatic brain injury. METHODS Br...
متن کاملAccuracy of a noninvasive temporal artery thermometer for use in infants.
OBJECTIVES To assess the accuracy of a new noninvasive temporal artery (TA) thermometer in infants; to compare the accuracy of the TA thermometer with that of a tympanic thermometer, using rectal thermometry as the criterion standard; and to compare the tolerability of the TA thermometer with that of the tympanic and rectal thermometers. DESIGN Prospective evaluation of the accuracy of TA and...
متن کاملInfra-red Thermal Imaging of the Inner Canthus: Correlates with the Temperature of the Injured Human Brain
Introduction: Infra-red (IR) thermometry is a safe and valid method to determine internal and surface temperature in human subjects. Under conditions of brain damage (head injury or stroke) knowledge of changes in the temperature of intracranial tissue is justified because of the vulnerability of neurons to accelerated damage at temperatures at the upper end of the febrile range. Aim: To determ...
متن کاملContinuous measurement of tympanic temperature with a new infrared method using an optical fiber.
The purpose of this study was to investigate the utility of an infrared tympanic thermometry by using an optical fiber for measuring tympanic temperature (Tty). In the head cooling and facial fanning tests during normothermia, right Tty measured by this method (infrared-Tty) and esophageal temperature (Tes) were not affected by decreased temple and forehead skin temperatures, suggesting that th...
متن کاملAn evaluation of tympanic thermometry in a paediatric emergency department.
BACKGROUND AND OBJECTIVES The consequences of missing fever in children can be grave. Body temperature is commonly recorded at the axilla but accuracy is a problem. This study aimed to evaluate the accuracy of a tympanic thermometer in the paediatric emergency setting. METHOD In a total of 106 infants, the body temperature was measured in the daytime with an infrared tympanic thermometer, and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the Royal Army Medical Corps
دوره 143 3 شماره
صفحات -
تاریخ انتشار 1997