Carotid artery stenting without post-stenting balloon dilatation
نویسندگان
چکیده
PURPOSE To evaluate the clinical outcome and MRI findings after carotid artery stenting (CAS) without post-dilatation. METHODS Between May 2005 and April 2012, a total of 169 consecutive patients (61.4% symptomatic) underwent 176 CAS procedures performed with an embolic protection device (GuardWire, n=116; FilterWire EZ, n=60). All stents were deployed without post-dilatation. Periprocedural complications and mid-term outcomes were analyzed. RESULTS The stroke rate was 2.3% within 30 days post-CAS (asymptomatic patients 1.5%; symptomatic patients 2.8%). Cerebral infarction occurred in one asymptomatic patient (1.5%) and one symptomatic patient (0.9%). Intracranial hemorrhage occurred in two symptomatic patients (1.9%). Post-CAS diffusion-weighted imaging (DWI) revealed a high-intensity area in 26 of 176 procedures (14.8%). Ipsilateral stroke after 31 days occurred in two patients (1.1%) and restenosis occurred in six (3.4%). A post-CAS comparison of the embolic protection devices revealed no difference in stroke incidence within 30 days and in DWI high-intensity area. CONCLUSIONS Our CAS procedure without post-dilatation is feasible, safe and associated with a low incidence of stroke and restenosis.
منابع مشابه
Carotid angioplasty and stenting in a patient with high grade stenosis of Internal Carotid Artery associated with both vertebral arteries and contralateral carotid occlusion
Severe internal carotid artery (ICA) stenosis is a common cause of cerebrovascular accident (CVA) in middle-aged patients. Contralateral carotid occlusion (CCO) in patients with severe ICA stenosis is associated with high risk of CVA. Carotid endarterectomy (CEA) is associated with more complications in patients with CCO than those without CCO. In this study, we present the case of a 61-year-ol...
متن کاملANGIOPLASTY AND STENTING OF CAROTID ARTERY STENOSIS WITH EMBOLIC PROTECTION DEVICES
Background: Carotid artery stenting (CAS) has recently been recommended as an alternative to carotid endarterectomy (CEA) by some clinicians. Objective: This study was designed to evaluate the success rate and in-hospital and 30-day adverse events in our first experiences in Iran for CAS with protection devices, to document our results and guide further use of CAS. Methods: From December 2...
متن کاملImmediate and Short-term Follow-Up of Aortic Coarctation Balloon Angioplasty and Stenting
Background Aortic Coarcatation (CoA) is one of the congenital heart diseases with the rate of 5-8% of Coronary heart diseases(CHDs). Balloon angioplasty is now one of the effective way of treatment for CoA, native or Re-coarctation (Re-CoA). We aimed to assess the immediate, and short term response to angioplasty and stenting, and also complications. Materials and Methods Balloon angioplasty wi...
متن کاملRescue Use of Tirofiban for Acute Carotid In-Stent Thrombosis
Carotid artery stenting is widely performed for extracranial carotid artery stenosis. In-stent thrombosis is a rare but potentially devastating complication. We present a case of acute in-stent thrombosis immediately following stent insertion and post-balloon dilatation in a 64-year-old male. Thrombosis was successfully treated by intravenous tirofiban, a glycoprotein IIb/IIIa receptor inhibitor.
متن کاملSafety of balloon pre-dilatation in the treatment of severe carotid artery stenosis.
AIM To assess early outcome of predilatation prior stenting of severe carotid artery stenosis and to evaluate early major adverse cardiovascular and cerebral events (MACCE). PATIENTS AND METHODS The study group consisted of 265 consecutive patients (200 males, 65 female, mean age 66.7 ± 8.6 years) in whom 275 percutaneous transluminal angioplasty (PTA) procedures of carotid arteries were perf...
متن کامل