Low Cost Device For Light Flicker Measurement
نویسندگان
چکیده
A new instrument for the evaluation of disturbances caused by variations in lamp voltage (light flicker) is proposed, based on light intensity measurements. Unlike current standard (IEC EN 61000-4-15), which determines flicker severity by filtering powering voltage measurements with a standard lamp model (230V/60W), the presented methodology includes the lamp itself in the measurement process, thus realizing an objective measurement of flicker. A testing station for the metrological characterization of the device has been implemented and measurements have been compared to a standard IEC flickermeter (Norma D6000). Thanks to its portability, the instrument can be used to measure light flicker over a wide range of environments spanning from home/office to rial locations.
منابع مشابه
Improving the Method of Location Identification and Determining the Effect of Each Flicker Source in Distribution Networks
Voltage flicker phenomenon is one of the main power quality problems in today's power networks. Before any compensation operation for this phenomenon, the location of each flicker sources must be identified and the effect of each of them on the network flicker value must be determined. Also, methods that require least number of monitoring points are more in demand due to the limitations of meas...
متن کاملA Comparison between SVC and STATCOM in Flicker Mitigation of Electric Arc Furnace using Practical Recorded Data
Electric arc furnace (EAF) is one of the largest loads in electric power systems. It is highly time varying and nonlinear. Its reactive power variations cause voltage fluctuations in nearby system which is known as flicker. On the other hand the nonlinear voltage-current characteristic causes strong voltage and current harmonics in EAF. To this end Flexible AC Transmission Systems (FACTS) techn...
متن کاملVoltage Flicker Parameters Estimation Using Shuffled Frog Leaping Algorithm and Imperialistic Competitive Algorithm
Measurement of magnitude and frequency of the voltage flicker is very important for monitoring andcontrolling voltage flicker efficiently to improve the network power quality. This paper presents twonew methods for measurement of flicker signal parameters using Shuffled Frog Leaping Algorithm(SFLA) and Imperialist Competitive Algorithm (ICA). This paper estimates fundamental voltage andflicker ...
متن کاملطیف نگاری ساختار DNA به کمک رنگدانه های مصنوعی با استفاده از نور LED
It is clear that DNA concentration and biological detection devices have many applications in the fields of genetics and biotechnology. For this goal, some similar devices have been designed working with the laser light which the disadvantages of them are high prices and the use of significant amounts of sample volume. But this designed device which works with LED light has very cheap manufactu...
متن کاملIn-House Handmade Camera for Indocyanine Green Video Angiography
Background and Aim: Vascular imaging during surgical procedures is very important and has many applications. There are several methods for intraoperative vascular assessment such as intraoperative angiography, Doppler, and fluorescence-based techniques. The latter group and specially the Indocyanine Green (ICG) Video Angiography (VA) is commonly used for vascular surgery and sentinel node...
متن کامل