Dependence of R2* bias on through-voxel frequency dispersion and gradient echo train in high-resolution 3D R2* mapping

نویسندگان

  • G. Helms
  • P. Dechent
چکیده

Introduction: The effective rate of decay of transverse magnetization, R2* = 1/T2*, is sensitive to B0 distortions at a mesoscopic scale (1). It is thus highly correlated to tissue concentrations of non-heme iron (2) and myelinated axons (3), especially at high and ultra-high field strengths (2-4). R2* is commonly measured using long-TR multi-slice gradient echo sequences. This approach implies high SNR and long echo trains, but limited resolution and increased sensitivity to through-voxel gradients in the slice direction. The latter have been modelled by linear dispersion imposing a sinc modulation on the exponential T2* decay (5). However, many fiber tracts and iron-containing nuclei involved in motor disease (like substantia nigra and subthalamic nucleus (6)) have a double-oblique orientation, so R2* measurements may be compromised by a 2D approach. 3D measurements at isotropic high resolution is also desirable for voxelbased statistical approaches (7) requiring spatial normalization. Here, the time required for the additional phase-encoding contrains TR and thus the duration of the gradient-echo train. Therefore, the behaviour of sinc model was studied for constraints of short gradient-echo train to guide the implementation of 3D R2* mapping scheme. Theory and simulations: The modulation of the sinc function is parameterized by the frequency dispersion Δν = γGΔx (in Hz/pixel) of a through-plane gradient G along the voxel dimension Δx. Up to the first root (or “node”), it is excellently approximated by its Taylor expansion: sinc(ΔνΤΕ) = sin(πΔνΤΕ)/(πΔνΤΕ) ≈ 1– (πΔνΤΕ)/6 + (πΔνΤΕ)/6/20 – (πΔνΤΕ)/6/20/42 . [1] The log signals S(TE) = S0 exp(R2*TE) sinc(ΔνΤΕ) are used, R2* and Δν appear at different order: log(S(TE)) ≈ log(S0) – R2*TE –(πΔνΤΕ)/6 – (πΔνΤΕ)/180 – (πΔνΤΕ)/2835; [2] so the dephasing correction can be implemented as polynomial regression. For standard linear regression, Eq. [2] predicts an addititive bias ΔR2* = R2*(fitted) – R2* that is independent of R2* and increases with Δν if Δν, if TEmax <<1. Log regression with different R2* and dispersion was simulation for TE sampling schemes reported for 3T (2-4,6,7) A steep increase of the ΔR2* offset was observed for if ΔνTEmax →1, so ΔR2* was fitted empirically by: ΔR2* = A Δν / [1 – ΔνTEmax] [3a] This was also used for the normalized S0 offset ΔS0/S0 = C Δν / [1 – ΔνTEmax] [3b] Experimental: 3D multi-echo FLASH imaging was performed on consenting healthy adults on a 3T whole-body system (Siemens Tim Trio) using an 8-channel receive-only head coil and the body coil for transmission. First, similar to (6), 8 bipolar echoes at multiples of TE = 4.92 ms with isotropic 1 mm resolution (non-selective excitation of 176 sagittal partitions, 256x176 mm field-of-view, TR/α=23 ms/6°). Measuring time using 6/8 partial Fourier (phase/partition) and 2x GRAPPA (24 reference lines, phase) was 6.5 minutes, respectively. FSL 4.0 (/www.fmrib.ox.ac.uk/fsl) was used for image-processing. After brain extraction, regression of order 1, 2, and 4 was performed on the log signals. The frequency offset was calculated from unwrapped phase images. Local gradients were derived by a differentiation kernel and used to correct R2* with parameters A and B determined by simulation. Results: Simulation: The dispersion related offset of R2* and S0 were independent of R2* and excellently described by Eqs.[3a,b] (Fig.1). Thus, longer echo trains are more sensitive to frequency dispersion. The initial increase A was correlated to the shortest TEmin, whereas a fewer number of echoes increased the exponent B. Experimental: Polynomial regression introduced errors into the R2* maps (Fig. 2) probably due to a correlation between the terms. Correction of R2* by Eq.[3a] introduced noise or failed probably due to oblique gradients (not shown). Figure 3 shows R2* overlays and histogram of the 3D acquisition. The high-resolution/short TE scheme yielded reliable R2* mapping down to the level of the pons and the cerebellum SN, with excessive bias (R2* > 50 sec) only in orbito-frontal and temporo-basal regions. Discussion: An empirical model for the influence of through-voxel gradients on R2* was derived from simulations, showing how the TE sampling scheme influences the sensitivity to frequency dispersion. 3D mapping of R2* advocates short gradient echo trains and high-resolution; thus confining the R2* bias to rather small sub-regions. This proved to be more feasible than correction. Non-selective excitation reduces the influence of small dispersion via a short TEmin. Despite the general trade-off between statistical error and sensitivity to bias, high-resolution R2* mapping of the brain seems feasible using 3D sequences at 3T. References: [1] Yablonskij, Haacke. MRM 32:749 (1994) [2] Yao et al.; NeuroImage 44:1259 (2009) [3] Li et al. MRM ePub (2009) [4] Peters et al. MRI 25:748 (2007) [5] Fernández-Seara, Wehrli. MRM 44:358 (2000) [6] Helms et al. Proc ISMRM 16 (2008) [7] Péran et al. JMRI 26:1413 (2007) Fig. 1: Simulated R2* offset Eq.[3a] and S0 offset Eq.[3b] for the schemes of refs 6 (o) and 7 (□)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Volumetric R2 * mapping using z-shim multi-echo gradient echo imaging.

PURPOSE To introduce macroscopic B0 field inhomogeneity-compensated volumetric R2 * mapping method with a three-dimensional (3D) z-shim multi-echo acquisition. METHODS The proposed z-shim sequence acquired conventional and z-shimmed echoes alternately with bipolar readout gradients. A constant-valued z-shim gradient was applied prior to each negative readout gradient lobe. A phase combination...

متن کامل

Consistency Assessment for R2 Measurements Obtained with Different Techniques at 7 Tesla

Introduction R2 relaxometry has been established as an important technique in various quantitative MR approaches [1, 2]. In practice, transverse relaxation of H nucleus usually deviates from the ideal mono-exponential decay due to the influences of various factors such as B0 inhomogeneity [3] and slice profile imperfection [4]. Free induction decay (FID) distortion causes discrepancy between R2...

متن کامل

MRI assessment of brain iron content in methamphetamine users

Introduction: Methamphetamine (MA) abuse produces long term changes to the dopamine system that likely contribute to the psychiatric and cognitive symptoms that are seen in MA users. Emerging evidence from preclinical studies suggests that brain iron accumulation plays a role in MA toxicity, both as a biomarker of damage and a potential source of oxidative stress; however, this relationship has...

متن کامل

The effects of voxel size and image smoothing on R2* measurements of the human brain

Introduction: Gradient echo imaging is gaining importance due to its high sensitivity to changes in tissue magnetic susceptibility, its fast data acquisition, with the growing number of ultra high field scanners and its low specific absorption rate. Quantitative imaging of the R2* relaxation rate employing multiple echoes can be used to assess blood oxygenation [1], for instance, or brain iron ...

متن کامل

Voxel-based Relaxometry of transverse relaxation rate with gradient echo R2(*) in patients with multiple system atrophy.

OBJECTIVE To explore the transverse relaxation rate with gradient echo R2(*) changes in patients with Parkinsonian variant of multiple system atrophy (MSA-P) with a voxel-based analysis of R2(*) map. METHODS Whole brain structural images and multi-echo T2(*) weighted image were acquired in 27 patients with probable MSA-P and 24 healthy individuals. R2(*) maps of the MSA-P were compared with t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009