3D volume reconstruction from serial breast specimen radiographs for mapping between histology and 3D whole specimen imaging.
نویسندگان
چکیده
PURPOSE In breast imaging, radiological in vivo images, such as x-ray mammography and magnetic resonance imaging (MRI), are used for tumor detection, diagnosis, and size determination. After excision, the specimen is typically sliced into slabs and a small subset is sampled. Histopathological imaging of the stained samples is used as the gold standard for characterization of the tumor microenvironment. A 3D volume reconstruction of the whole specimen from the 2D slabs could facilitate bridging the gap between histology and in vivo radiological imaging. This task is challenging, however, due to the large deformation that the breast tissue undergoes after surgery and the significant undersampling of the specimen obtained in histology. In this work, we present a method to reconstruct a coherent 3D volume from 2D digital radiographs of the specimen slabs. METHODS To reconstruct a 3D breast specimen volume, we propose the use of multiple target neighboring slices, when deforming each 2D slab radiograph in the volume, rather than performing pairwise registrations. The algorithm combines neighborhood slice information with free-form deformations, which enables a flexible, nonlinear deformation to be computed subject to the constraint that a coherent 3D volume is obtained. The neighborhood information provides adequate constraints, without the need for any additional regularization terms. RESULTS The volume reconstruction algorithm is validated on clinical mastectomy samples using a quantitative assessment of the volume reconstruction smoothness and a comparison with a whole specimen 3D image acquired for validation before slicing. Additionally, a target registration error of 5 mm (comparable to the specimen slab thickness of 4 mm) was obtained for five cases. The error was computed using manual annotations from four observers as gold standard, with interobserver variability of 3.4 mm. Finally, we illustrate how the reconstructed volumes can be used to map histology images to a 3D specimen image of the whole sample (either MRI or CT). CONCLUSIONS Qualitative and quantitative assessment has illustrated the benefit of using our proposed methodology to reconstruct a coherent specimen volume from serial slab radiographs. To our knowledge, this is the first method that has been applied to clinical breast cases, with the goal of reconstructing a whole specimen sample. The algorithm can be used as part of the pipeline of mapping histology images to ex vivo and ultimately in vivo radiological images of the breast.
منابع مشابه
Three-Dimensional Surface Imaging is an Effective Tool for Measuring Breast Volume: A Validation Study
BACKGROUND Accurate breast volume assessment is a prerequisite to preoperative planning, as well as intraoperative decision making in breast reconstruction surgery. The use of three-dimensional surface imaging (3D scanning) to assess breast volume has many advantages. However, before employing 3D scanning in the field, the tool's validity should be demonstrated. The purpose of this study was to...
متن کاملUltra-Fast Image Reconstruction of Tomosynthesis Mammography Using GPU
Digital Breast Tomosynthesis (DBT) is a technology that creates three dimensional (3D) images of breast tissue. Tomosynthesis mammography detects lesions that are not detectable with other imaging systems. If image reconstruction time is in the order of seconds, we can use Tomosynthesis systems to perform Tomosynthesis-guided Interventional procedures. This research has been designed to study u...
متن کاملThree Dimensional Cone-beam Reconstruction of Micro Computed Tomography in the Breast Specimen
Traditionally, the specimen obtained from a breast biopsy can only be examined by a microscope. Although the resolution of microscope is high, it can only examine one thin section at a time. Hence, the microcalcifications next to the observed section may be missed. To solve for this problem, we acquire the specimen by a 3D micro computed tomography (microCT) with electron bombarded charged coup...
متن کاملWhole Brain Reconstruction from Multilayered Sections of a Mouse Model of Status Epilepticus
This research concerns confocal fluorescence microscopy imaging of the whole brain of C57BL/6 mice with singlecell resolution. These brains are too large for specimen holders in available 3D microscopes, so this research develops a set of volume reconstruction methods to reproduce a whole brain from multilayered, thin sections of the brain imaged using a confocal microscope. As the sections are...
متن کاملFully automatic and robust 3D registration of serial-section microscopic images
Robust and fully automatic 3D registration of serial-section microscopic images is critical for detailed anatomical reconstruction of large biological specimens, such as reconstructions of dense neuronal tissues or 3D histology reconstruction to gain new structural insights. However, robust and fully automatic 3D image registration for biological data is difficult due to complex deformations, u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 44 3 شماره
صفحات -
تاریخ انتشار 2017