Influence of data processing on cyclic variation of integrated backscatter and wall thickness in stunned porcine myocardium.
نویسندگان
چکیده
This study was performed to investigate the relationship between the cyclic variation of integrated backscatter and myocardial wall thickening in stunned myocardium. Different definitions of cyclic variation were evaluated to be able to compare with other studies. Ultrasound data were acquired from 10 open-chested Yorkshire pigs (25-33 kg) at baseline, during regional ischemia and during 30 min of stunning, using a broadband ultrasound transducer (3-7 MHz) sutured directly upon the left ventricular myocardial wall. Cyclic variation of integrated backscatter and myocardial wall thickening were calculated using three definitions obtained from the literature. Independent of the definition, cyclic variation of wall thickness and integrated backscatter were blunted during acute ischemia and returned transiently to or above baseline during the first minute of reperfusion, followed by a gradual decrease to a level under baseline during stunning. An early return of the cyclic variation of the integrated backscatter was not observed in pigs, independent of the data processing used. The relationship between integrated backscatter and wall thickness was maintained.
منابع مشابه
The relationship between myocardial integrated backscatter, perfusion pressure and wall thickness during isovolumic contraction: an isolated pig heart study.
To investigate the independent effect of myocardial wall thickness and myocardial perfusion pressure on integrated backscatter, experiments were designed in which integrated backscatter of normally perfused myocardial tissue was measured while changes in wall thickness during the cardiac cycle were reduced to a minimum. In nine blood-perfused isolated pig hearts, perfusion pressure was uncouple...
متن کاملUltrasonic tissue characterization with integrated backscatter. Acute myocardial ischemia, reperfusion, and stunned myocardium in patients.
We have previously shown in studies of experimental animals that myocardium exhibits a cardiac cycle-dependent variation of integrated backscatter that reflects regional myocardial contractile performance and that is blunted promptly after arterial occlusion and recovers after reperfusion. To define the clinical utility of ultrasonic tissue characterization with integrated backscatter for detec...
متن کاملSerial measurement of integrated ultrasonic backscatter in human cardiac allografts for the recognition of acute rejection.
Cyclic variation of integrated ultrasonic backscatter (IB) was noninvasively measured in the septum and left ventricular posterior wall using a quantitative IB imaging system to assess the alterations in the acoustic properties of myocardium associated with acute cardiac allograft rejection. The study population consisted of 23 cardiac allograft recipients and 18 normal subjects. In each cardia...
متن کاملThe dependence of myocardial ultrasonic integrated backscatter on contractile performance.
We have recently shown that the cardiac cycle-dependent variation in myocardial ultrasonic integrated backscatter is blunted with regional ischemia in dogs. To determine if global and intramural regional myocardial contractile performance can be quantified by integrated backscatter, we analyzed ultrasonic responses after induction of increased and decreased contractility in five dogs. A recentl...
متن کاملMyocardium in Patients
We have previously shown in studies of experimental animals that myocardium exhibits a cardiac cycle-dependent variation of integrated backscatter that reflects regional myocardial contractile performance and that is blunted promptly after arterial occlusion and recovers after reperfusion. To define the clinical utility of ultrasonic tissue characterization with integrated backscatter for detec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ultrasound in medicine & biology
دوره 23 3 شماره
صفحات -
تاریخ انتشار 1997