Superbugs on Duodenoscopes: the Challenge of Cleaning and Disinfection of Reusable Devices.

نویسندگان

  • Romney M Humphries
  • Gerald McDonnell
چکیده

Inadequate flexible endoscope reprocessing has been associated with infection outbreaks, most recently caused by carbapenem-resistant Enterobacteriaceae. Lapses in essential device reprocessing steps such as cleaning, disinfection/sterilization, and storage have been reported, but some outbreaks have occurred despite claimed adherence to established guidelines. Recommended changes in these guidelines include the use of sterilization instead of high-level disinfection or the use of routine microbial culturing to monitor efficacy of reprocessing. This review describes the current standards for endoscope reprocessing, associated outbreaks, and the complexities associated with both microbiological culture and sterilization approaches to mitigating the risk of infection associated with endoscopy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multisociety guideline on reprocessing flexible GI endoscopes: 2016 update.

1,2 The beneficial role of GI endoscopy for the prevention, diagnosis, and treatment of many digestive diseases and cancer iswell established. Likemany sophisticatedmedical devices, the endoscope is a complex, reusable instrument that requires meticulous cleaning and reprocessing in strict accordance with manufacturer and professional organization guidance before being used on subsequent patien...

متن کامل

Monitoring and improving the effectiveness of cleaning medical and surgical devices.

The overall risk of infection from medical devices is very low, but high infection transmission rates have been related to inadequate reprocessing of arthroscopic shavers and flexible duodenoscopes. Monitoring of manual and automated cleaning is needed to ensure that inadequately cleaned medical devices are recleaned prior to disinfection or sterilization.

متن کامل

Current Issues in Duodenoscope-Associated Infections: Now Is the Time to Take Action

A duodenoscope has a very complex structure that contains many small parts which make reprocessing more challenging. The difficulty in cleaning duodenoscopes contributes to a higher risk of infection than that of conventional gastrointestinal endoscopes. However, a duodenoscope shares similar disinfection process with other gastrointestinal endoscopes. Recent outbreaks of carbapenem-resistant E...

متن کامل

Gastrointestinal endoscopes: a need to shift from disinfection to sterilization?

More than 10 million gastrointestinal endoscopic procedures areperformedannually in theUnitedStates fordiagnosticpurposes, therapeutic interventions, or both.1 Because gastrointestinalendoscopescontactmucosal surfaces,useofacontaminated endoscope may lead to patient-to-patient transmission of potential pathogens with a subsequent risk of infection.1 In this issue of JAMA, Epstein and colleagues...

متن کامل

The role of biofilms in reprocessing medical devices.

Biofilms are communities of microorganisms within extracellular polymeric material attached to surfaces. Within a biofilm, cells have some protection from drying and other stress factors in their environment, including antimicrobial agents. In this article, the challenges to medical device reprocessing posed by biofilms are addressed. Biofilm formation on reusable medical device surfaces is a r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 53 10  شماره 

صفحات  -

تاریخ انتشار 2015