Normal limits for left ventricular ejection fraction and volumes determined by gated single photon emission computed tomography – a comparison between two quantification methods

نویسندگان

  • Milan Lomsky
  • Lena Johansson
  • Peter Gjertsson
  • Jonas Björk
  • Lars Edenbrandt
چکیده

To compare gender-related normal limits for left ventricular (LV) ejection fraction (EF), end-diastolic and end-systolic volumes (EDV and ESV), obtained using two myocardial perfusion-gated single photon emission computed tomography (SPECT) quantification methods. A total of 185 patients were retrospectively selected from a consecutive series of patients examined for coronary artery disease (CAD) or for management of known CAD. Patients were included in the study group if they had normal or probably normal results with stress and rest perfusion imaging and if the combined interpretation of perfusion studies and gated rest studies showed no signs or suspicion of myocardial infarction. The gated SPECT studies were performed using a 2-day stress/gated rest Tc-99m sestamibi protocol. All patient studies were processed using CAFU and quantitative-gated SPECT (QGS), the two software packages for quantification of gated SPECT images. The lower normal limits for EF were higher for CAFU compared with QGS for both women (59% versus 53%) and men (54% versus 47%). The upper normal limits for EDV were also higher for CAFU compared with QGS for both women (133 versus 107 ml) and men (182 versus 161 ml). The differences between the software packages were small for ESV (women 44 versus 44 ml; men 69 versus 74 ml). Gender-specific normal limits need to be applied for LV EF and volumes determined by gated SPECT. Separate criteria for abnormal LV EF and EDV need to be used for women and men depending on the software package used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography

Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...

متن کامل

Comparison of left ventricular ejection fraction values obtained using invasive contrast left ventriculography, two-dimensional echocardiography, and gated single-photon emission computed tomography

OBJECTIVES Left ventricular ejection fraction can be measured by a variety of invasive and non-invasive cardiac techniques. This study assesses the relation of three diagnostic modalities to each other in the measurement of left ventricular ejection fraction: invasive contrast left ventriculography, two-dimensional echocardiography, and quantitative gated single-photon emission computed tomogra...

متن کامل

Evaluation of left ventricular wall motion, volumes, and ejection fraction by gated myocardial tomography with technetium 99m-labeled tetrofosmin: a comparison with cine magnetic resonance imaging.

BACKGROUND Whether left ventricular function can be assessed accurately by gated single photon emission computed tomography (SPECT) in patients with myocardial infarction and severe perfusion defects is not well known. METHODS AND RESULTS Twenty-five patients with an acute myocardial infarction underwent 99mTc-labeled tetrofosmin (99mTc-tetrofosmin) gated SPECT and cine magnetic resonance ima...

متن کامل

Assessment of global and regional left ventricular function by electrocardiographic gated N-13 ammonia positron emission tomography in patients with coronary artery disease.

BACKGROUND Electrocardiographic gated 13N-ammonia positron emission tomography (PET) enables simultaneous assessment of myocardial blood flow and left ventricular (LV) function. The aim of this study was to assess the accuracy of gated 13N-ammonia PET for evaluating global and regional LV function in patients with coronary artery disease (CAD) in comparison with conventional left ventriculograp...

متن کامل

A new automated method for analysis of gated-SPECT images based on a three-dimensional heart shaped model.

A new automated method for quantification of left ventricular function from gated-single photon emission computed tomography (SPECT) images has been developed. The method for quantification of cardiac function (CAFU) is based on a heart shaped model and the active shape algorithm. The model contains statistical information of the variability of left ventricular shape. CAFU was adjusted based on...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical Physiology and Functional Imaging

دوره 28  شماره 

صفحات  -

تاریخ انتشار 2008