Spoiled & Balanced Gradient Echo Methods

نویسنده

  • Oliver Bieri
چکیده

Imaging with spoiled, balanced or nonbalanced gradient echo (GRE) refers to a class of fast imaging sequences that use a dynamic equilibrium or steady state signal for imaging. As originally introduced in 1958 by Carr (1) for NMR spectroscopy, a dynamic equilibrium or steadystate can be established by a train of radio-frequency (RF) excitation pulses interleaved by periods of ‘free precession’, referred to as steady state free precession (SSFP) (see Fig. 1).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast Gradient Echo Sequences Including Balanced SSFP

Many common magnetic resonance imaging sequences are classified either as spin echo or gradient echo techniques. Generally, a gradient echo occurs when spins are coherent regardless of their position within the sample. This occurs whenever the net gradient area since a previous echo is zero. In a spin echo, spins are coherent regardless of their resonance frequency [1]. Here we will focus on gr...

متن کامل

Free-breathing myocardial T1 mapping using magnetization-prepared slice interleaved spoiled gradient echo imaging

Background Quantitative myocardial T1 mapping and extracellular volume fraction (ECV) show promise for non-invasive assessment of cardiomyopathies. Most available T1 mapping sequences use a single slice breath-hold acquisition with balanced steady state free precession (b-SSFP) readout [1]. However, b-SSFP readout is sensitive to B0 field inhomogeneity and is potentially T2 dependent [1]. In th...

متن کامل

Evaluation of a free-breathing myocardial T1 mapping using magnetization-prepared slice interleaved spoiled gradient echo imaging in patient

Background Quantitative myocardial T1 mapping shows promise for assessment of various cardiomyopathies. Most available sequences are generally acquired within a breath-hold using a balanced SSFP (bSSFP) imaging readout. However, the signal obtained from a bSSFP imaging readout is T2 dependent, sensitive to magnetization transfer and has increased susceptibility to the B0 field inhomogeneity lea...

متن کامل

Liver lesion conspicuity during real-time MR-guided radiofrequency applicator placement using spoiled gradient echo and balanced steady-state free precession imaging.

PURPOSE To retrospectively evaluate the conspicuity of liver lesions in a fluoroscopic spoiled gradient echo (GRE) and a balanced steady-state free precession (SSFP) magnetic resonance imaging (MRI) sequence. MATERIALS AND METHODS In all, 103 patients with hepatocellular carcinomas (HCC) (41) or liver metastases (67) were treated using MR-guided radiofrequency ablation in a wide-bore 1.5 T sc...

متن کامل

Free-breathing 3D cardiac function with accelerated magnetization transfer prepared imaging

Background 3D cardiac MRI has long held promise for improved heart coverage, higher resolution, and reduced sensitivity to poor breath-hold reproducibility. However, its use has been limited by reduced blood pool to myocardium contrast for spoiled and balanced steady-state free precession (bSSFP) implementations. T2-preparation techniques [1] are capable of increasing contrast but are unfortuna...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011