AIM To analyze planning total hip arthroplasty (THA) with an additional anteroposterior hip view may increases the accuracy of preoperative planning in THA. METHODS We conducted prospective digital planning in 100 consecutive patients: 50 of these procedures were planned using pelvic overview only (first group), and the other 50 procedures were planned using pelvic overview plus antero-posterior (a.p.) hip view (second group). The planning and the procedure of each patient were performed exclusively by the senior surgeon. Fifty procedures with retrospective analogues planning were used as the control group (group zero). After the procedure, the planning was compared with the eventually implanted components (cup and stem). For statistic analysis the χ 2 test was used for nominal variables and the t test was used for a comparison of continuous variables. RESULTS Preoperative planning with an additional a.p. hip view (second group) significantly increased the exact component correlation when compared to pelvic overview only (first group) for both the acetabular cup and the femoral stem (76% cup and 66% stem vs 54% cup and 32% stem). When considering planning ± 1 size, the accuracy in the second group was 96% (48 of 50 patients) for the cup and 94% for the stem (47 of 50 patients). In the analogue control group (group zero), an exact correlation was observed in only 1/3 of the cases. CONCLUSION Digital THA planning performed by the operating surgeon and based on additional a.p. hip view significantly increases the correlation between preoperative planning and eventual implant sizes.
منابع مشابه
Effect of training level on accuracy of digital templating in primary total hip and knee arthroplasty.
The use of digital radiography and templating software continues to become more prevalent in orthopedics as the number of total hip arthroplasty (THA) and total knee arthroplasty (TKA) procedures increases every year. The purpose of this study was to evaluate the effect of training level on the accuracy of digital templating for primary THA and TKA. Digital radiographs of 97 patients undergoing...
متن کاملDigital versus conventional templating techniques in preoperative planning for total hip arthroplasty.
BACKGROUND The purpose of our investigation was to compare a digital templating system to conventional templating techniques when preoperatively planning for total hip arthroplasty. METHODS We included 18 consecutive patients with primary osteoarthritis undergoing uncemented total hip arthroplasty in our study. At separate sittings, we independently conducted preoperative templating. They per...
متن کاملAccuracy and Reliability of Preoperative On-screen Templating Using Digital Radiographs for Total Hip Arthroplasty
PURPOSE Preoperative on-screen templating is a method of using acetate templates on digital images. The aim of the present study was to evaluate the accuracy, intra- and interobserver reliabilities of preoperative on-screen templating using digital radiographs for total hip arthroplasty (THA). MATERIALS AND METHODS Two hundred patients with hip disease who were treated with primary cementless...
متن کاملComparing the accuracy of radiographic preoperative digital templating for a second- versus a first-generation THA stem.
This study assessed the accuracy of preoperative digital templating for a second-generation cementless stem compared with its first-generation design. A prospective cohort of 100 consecutive patients who had undergone a primary total hip arthroplasty using a new second-generation cementless stem was compared with the prior 100 hips that had received the first-generation stem. The authors believ...
متن کاملVariance in predicted cup size by 2-dimensional vs 3-dimensional computerized tomography–based templating in primary total hip arthroplasty
Background Preoperative total hip arthroplasty templating can be performed with radiographs using acetate prints, digital viewing software, or with computed tomography (CT) images. Our hypothesis is that 3D templating is more precise and accurate with cup size prediction as compared to 2D templating with acetate prints and digital templating software. Methods Data collected from 45 patients u...