Visualization of HIFU-induced lesion boundaries by axial-shear strain elastography: a feasibility study.

نویسندگان

  • Arun K Thittai
  • Belfor Galaz
  • Jonathan Ophir
چکیده

In this paper, we report on a study that investigated the feasibility of reliably visualizing high-intensity focused ultrasound (HIFU) lesion boundaries using axial-shear strain elastograms (ASSE). The HIFU-induced lesion cases used in the present work were selected from data acquired in a previous study. The samples consisted of excised canine livers with thermal lesions produced by a magnetic resonance-compatible HIFU system (GE Medical System, Milwaukee, WI, USA) and were cast in a gelatin block for the elastographic experiment. Both single and multiple HIFU-lesion samples were investigated. For each of the single-lesion samples, the lesion boundaries were determined independently from the axial strain elastogram (ASE) and ASSE at various iso-intensity contour thresholds (from -2 dB to -6 dB), and the area of the enclosed lesion was computed. For samples with multiple lesions, the corresponding ASSE was analyzed for identifying any unique axial-shear strain zones of interest. We further performed finite element modeling (FEM) of simple two-inclusion cases to verify whether the in vitro ASSE obtained were reasonable. The results show that the estimation of the lesion area using ASSE is less sensitive to iso-intensity threshold selection, making this method more robust compared with the ASE-based method. For multiple lesion cases, it was shown that ASSE enables high-contrast visualization of a "thin" untreated region in between multiple fully-treated HIFU-lesions. This contrast visualization was also noticed in the FEM predictions. In summary, the results demonstrate that it is feasible to reliably visualize HIFU lesion boundaries using ASSE.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Visualization of bonding at an inclusion boundary using axial-shear strain elastography: a feasibility study.

Ultrasound elastography produces strain images of compliant tissues under quasi-static compression. In axial-shear strain elastography, the local axial-shear strain resulting from application of quasi-static axial compression to an inhomogeneous material is imaged. The overall hypothesis of this work is that the pattern of axial-shear strain distribution around the inclusion/background interfac...

متن کامل

Temperature effect in high intensity focused ultrasound therapy control using dynamic MR elastography

High intensity focused ultrasound (HIFU) is a method for non-invasive tumor therapy. The high energy density in the focal spot leads to local tissue heating and finally to thermal coagulation in the focal area (Fig.1) [1]. To monitor this treatment, the focus position can be detected online with temperature sensitive MR imaging. However characterization of the induced lesion is difficult. It ha...

متن کامل

Resolution of axial shear strain elastography.

The technique of mapping the local axial component of the shear strain due to quasi-static axial compression is defined as axial shear strain elastography. In this paper, the spatial resolution of axial shear strain elastography is investigated through simulations, using an elastically stiff cylindrical lesion embedded in a homogeneously softer background. Resolution was defined as the smallest...

متن کامل

Breast tumor classification using axial shear strain elastography: a feasibility study.

Recently, the feasibility of visualizing the characteristics of bonding at an inclusion-background boundary using axial-shear strain elastography was demonstrated. In this paper, we report a feasibility study on the utility of the axial-shear strain elastograms in the classification of in vivo breast tumor as being benign or malignant. The study was performed using data sets obtained from 15 be...

متن کامل

Elastographic characterization of HIFU-induced lesions in canine livers.

The elastographic visualization and evaluation of high-intensity focused ultrasound (HIFU)-induced lesions were investigated. The lesions were induced in vitro in freshly excised canine livers. The use of different treatment intensity levels and exposure times resulted in lesions of different sizes. Each lesion was clearly depicted by the corresponding elastogram as being an area harder than th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ultrasound in medicine & biology

دوره 37 3  شماره 

صفحات  -

تاریخ انتشار 2011