The ISO Standard 14577 for Mechanics Violates the First Energy Law and Denies Physical Dimensions

ثبت نشده
چکیده

The basis of the quantitative conical/pyramidal (nano) indentation, without fittings, iterations, or simulations, is the physically founded FN=k h 3/2 relation. The constant k (penetration resistance, mN/μm3/2) from linear plot with excellent regression discards initial surface effects, identifies important phase transformation onsets, conversion and activation energies, and reveals errors. The failing Sneddon theory of ISO with unphysical exponent 2 on h lacks these possibilities, disregards shear-force work, and violates the first energy law since 50 years. The denied but strictly quantified loss of energy (20% for physical h3/2; 33.33% at believed h2) violates the first energy law and disregards the force remaining for penetration. Straightforward correction is performed for the dimensions, by replacing unphysical exponent 2. The correction factors hmax 1/2 and 0.8 are applied via joint maximal force to the universal, FE-simulated, (approximately) ISO hardness, and ISO modulus that unduly rely on h2, to give the physically founded values with their correct dimensions. Previous corrected k-values obtain Hphys directly from the loading curve regression. Previous incomplete corrections are rectified. The new dimensions and daily risk liabilities from ISO versus physics dilemma are discussed, considering the influence on all mechanical parameters from hardness and modulus, regarding technique, biology, medicine, daily life. *Corresponding author: Kaupp G, University of Oldenburg, Diekweg 15 D-26188 Edewecht, Germany, Tel: 4944868386; Fax: 494486920704; E-mail: [email protected] Received January 24, 2017; Accepted February 08, 2017; Published February 18, 2017 Citation: Kaupp G (2017) The ISO Standard 14577 for Mechanics Violates the First Energy Law and Denies Physical Dimensions. J Material Sci Eng 6: 321. doi: 10.4172/2169-0022.1000321 Copyright: © 2017 Kaupp G. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Important Consequences of the Exponent 3/2 for Pyramidal/Conical Indentations-New Definitions of Physical Hardness and Modulus

The now physically founded exponent 3/2 that governs the relation of normal force to depth3/2 in conical/pyramidal indentation is a physically founded (FN = k h 3/2). Strictly linear plots obtain non-iterated penetration resistance k (mN/ μm3/2) as slope, initial effects (including tip rounding), adhesion energy, and phase transitions with their transformation energy and activation energy. The ...

متن کامل

How the Nonextensivity Parameter Affects Energy Fluctuations

In this article, the effect of the nonextensivity parameter on the energy fluctuations of nonextensive systems is studied in two different versions of the Tsallis statistical mechanics. Once a general expression has been reported for the energy fluctuations in the second version (Tsallis work in 1988), the energy fluctuations of an ideal gas and a harmonic oscillator are studied in the second a...

متن کامل

Buckling Analysis of Functionally Graded Shallow Spherical Shells Under External Hydrostatic Pressure

The aim of this paper is to determine the critical buckling load for simply supported thin shallow spherical shells made of functionally graded material (FGM) subjected to uniform external pressure. A metal-ceramic functionally graded (FG) shell with a power law distribution for volume fraction is considered, where its properties vary gradually through the shell thickness direction from pure me...

متن کامل

Proposing a quantitative approach to measure the success of energy management systems in accordance with ISO 50001: 2011 using an analytical hierarchy process (AHP)

ISO 50001: 2011 provides an integrated and systematic framework to plan, implement, operate, certify, and maintain energy management systems (EMSs). Evaluation of organizations in relation to meeting the standard requirements is performed by an auditing qualitative approach. In this research, a quantitative approach has been proposed and implemented to assess organizations and rank them based o...

متن کامل

Comparison of Hospital standards with ISO principles and presentation appropriate model of Hospital standard development

Background: Hospital standards are one of the valuest concepture items in an organization and hospital management. The research purpose was determination of luchs of hospital evaluation current way throght the comparission with ISO quality management standards and suggestion of a model to hospital standard development based on aquired findings. Materials & Methods: This research is a descripti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017