How do annuloplasty rings affect mitral annular strains in the normal beating ovine heart?

نویسندگان

  • Wolfgang Bothe
  • Manuel K Rausch
  • John-Peder Escobar Kvitting
  • Dominique K Echtner
  • Mario Walther
  • Neil B Ingels
  • Ellen Kuhl
  • D Craig Miller
چکیده

BACKGROUND We hypothesized that annuloplasty ring implantation alters mitral annular strains in a normal beating ovine heart preparation. METHODS AND RESULTS Sheep had 16 radiopaque markers sewn equally spaced around the mitral annulus. Edwards Cosgrove partial flexible band (COS; n=12), St Jude complete rigid saddle-shaped annuloplasty ring (RSA; n=10), Carpentier-Edwards Physio (PHY; n=11), Edwards IMR ETlogix (ETL; n=11), and GeoForm (GEO; n=12) annuloplasty rings were implanted in a releasable fashion. Four-dimensional marker coordinates were obtained using biplane videofluoroscopy with the ring inserted (ring) and after ring release (control). From marker coordinates, a functional spatio-temporal representation of each annulus was generated through a best fit using 16 piecewise cubic Hermitian splines. Absolute total mitral annular ring strains were calculated from the relative change in length of the tangent vector to the annular curve as strains occurring from control to ring state at end-systole. In addition, average Green-Lagrange strains occurring from control to ring state at end-systole along the annulus were calculated. Absolute total mitral annular ring strains were smallest for COS and greatest for ETL. Strains for RSA, PHY, and GEO were similar. Except for COS in the septal mitral annular segment, all rings induced compressive strains along the entire annulus, with greatest values occurring at the lateral mitral annular segment. CONCLUSIONS In healthy, beating ovine hearts, annuloplasty rings (COS, RSA, PHY, ETL, and GEO) induce compressive strains that are predominate in the lateral annular region, smallest for flexible partial bands (COS) and greatest for an asymmetrical rigid ring type with intrinsic septal-lateral downsizing (ETL). However, the ring type with the most drastic intrinsic septal-lateral downsizing (GEO) introduced strains similar to physiologically shaped rings (RSA and PHY), indicating that ring effects on annular strain profiles cannot be estimated from the degree of septal-lateral downsizing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

How Do Annuloplasty Rings Affect Mitral Annular Strains in the Normal Beating Ovine

Wolfgang Bothe, Manuel K. Rausch, John-Peder Escobar Kvitting, Dominique K. Echtner, Heart? How Do Annuloplasty Rings Affect Mitral Annular Strains in the Normal Beating Ovine Print ISSN: 0009-7322. Online ISSN: 1524-4539 Copyright © 2012 American Heart Association, Inc. All rights reserved. is published by the American Heart Association, 7272 Greenville Avenue, Dallas, TX 75231 Circulation doi...

متن کامل

Rigid, complete annuloplasty rings increase anterior mitral leaflet strains in the normal beating ovine heart.

BACKGROUND Annuloplasty ring or band implantation during surgical mitral valve repair perturbs mitral annular dimensions, dynamics, and shape, which have been associated with changes in anterior mitral leaflet (AML) strain patterns and suboptimal long-term repair durability. We hypothesized that rigid rings with nonphysiological three-dimensional shapes, but not saddle-shaped rigid rings or fle...

متن کامل

Anterior mitral leaflet curvature in the beating ovine heart: a case study using videofluoroscopic markers and subdivision surfaces.

The implantation of annuloplasty rings is a common surgical treatment targeted to re-establish mitral valve competence in patients with mitral regurgitation. It is hypothesized that annuloplasty ring implantation influences leaflet curvature, which in turn may considerably impair repair durability. This research is driven by the vision to design repair devices that optimize leaflet curvature to...

متن کامل

Surgery for Valvular Heart Disease Three-Dimensional Echocardiographic Analysis of Mitral Annular Dynamics Implication for Annuloplasty Selection

Background—Proponents of flexible annuloplasty rings have hypothesized that such devices maintain annular dynamics. This hypothesis is based on the supposition that annular motion is relatively normal in patients undergoing mitral valve repair. We hypothesized that mitral annular dynamics are impaired in ischemic mitral regurgitation and myxomatous mitral regurgitation. Methods and Results—A Ph...

متن کامل

Paneth suture annuloplasty abolishes acute ischemic mitral regurgitation but preserves annular and leaflet dynamics.

BACKGROUND Ring annuloplasty, the standard treatment for ischemic mitral regurgitation (IMR), abolishes normal annular dynamics and freezes the posterior leaflet. We examined the impact of Paneth suture annuloplasty during acute IMR on motion of the mitral annulus and leaflets in an ovine model. METHODS AND RESULTS Eight sheep had radiopaque markers placed on the left ventricle, anterior mitr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 126 11 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2012