Fluorescence-based blood coagulation assay device for measuring activated partial thromboplastin time.

نویسندگان

  • Magdalena M Dudek
  • Nigel Kent
  • Kerstin M Gustafsson
  • Tomas L Lindahl
  • Anthony J Killard
چکیده

The measurement of blood clotting time is important in a range of clinical applications such as assessing coagulation disorders and controlling the effect of various anticoagulant drug therapies. Clotting time tests essentially measure the onset of clot formation which results from the formation of fibrin fibers in the blood sample. However, such assays are inherently imprecise due to the highly variable nature of the clot formation process and the sample matrix. This work describes a clotting time measurement assay which uses a fluorescent probe to very precisely detect the onset of fibrin clot formation. It uses a microstructured surface which enhances the formation of multiple localized clot loci and which results in the abrupt redistribution of the fluorescent label at the onset of clot formation in both whole blood and plasma. This methodology was applied to the development of an activated partial thromboplastin time (aPTT) test in a lateral flow microfluidic platform and used to monitor the effect of heparin dosage where it showed linearity from 0 to 2 U/mL in spiked plasma samples (R(2)=0.996, n = 3), correlation against gold standard coagulometry of 0.9986, and correlation against standard hospital aPTT in 32 patient samples of 0.78.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Fondaparinux on Coagulation Assays

● Context.—Fondaparinux, a factor Xa inhibitor, is approved for thromboprophylaxis after orthopedic surgery and for treatment of venous thromboembolism. It may also be efficacious, safe, and cost-effective for other patients; thus, more widespread use of fondaparinux is likely. The effect of fondaparinux on coagulation testing needs to be thoroughly examined. Objective.—To report the effects of...

متن کامل

Comparison of factor deficient plasmas for measuring Factor VIII and IX

Introduction Factor dosages are part of the diagnostic work up in patients with bleeding tendency (factor (F) VIII and FIX) or in thrombophilia screening (FVIII). The correct diagnosis of FVIII and FIX deficiency and the assessment of severity of the disease are essential for a patient-tailored treatment strategy. Persistently high levels of FVIII are regarded as a thrombophilia risk marker. FV...

متن کامل

Update for Nurse Anesthetists Thromboelastography: Clinical Application, Interpretation, and Transfusion Management

Introduction The coagulation cascade is a dynamic process dependent on many factors. It involves interaction between primary hemostasis, platelet clot formation, secondary hemostasis, thrombin generation, and fibrinolysis. The assessment of this process is particularly important in the surgical patient to properly assess patient coagulation assessment, manage hemostatic therapy and transfusion ...

متن کامل

Methods for differential diagnosis of consumption coagulopathy.

In order to find out the sensitive tests to differentiate intravascular coagula tion from intravascular proteolysis, the changes in factors of coagulation fibrinolysis were studied on experimentally produced fibrinolysis, fibrinogenolysis and intravascular coagulation. Fibrinogen, and factors V and VIII were decreased; the prothrombin time, thrombin time and partial thromboplastin time were pro...

متن کامل

Clotting, activated partial thromboplastin and coagulation times in monitoring heparin therapy.

The automated-activated coagulation time, manual-activated coagulation time and the activated partial thromboplastin time were compared to the whole blood clotting time in the measurement of hypocoagulation of heparinized blood. The normal ranges and degree of reproducibility were determined for each clotting assay. Each method was examined for its sensitivity to various concentrations of hepar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 83 1  شماره 

صفحات  -

تاریخ انتشار 2011