Intrathoracic Fat Measurements Using Multidetector Computed Tomography (MDCT): Feasibility and Reproducibility.

نویسندگان

  • Jadranka Stojanovska
  • El-Sayed H Ibrahim
  • Aamer R Chughtai
  • Elizabeth A Jackson
  • Barry H Gross
  • Jon A Jacobson
  • Alexander Tsodikov
  • Brian Daneshvar
  • Benjamin D Long
  • Thomas L Chenevert
  • Ella A Kazerooni
چکیده

Intrathoracic fat volume, more specifically, epicardial fat volume, is an emerging imaging biomarker of adverse cardiovascular events. The purpose of this work is to show the feasibility and reproducibility of intrathoracic fat volume measurement applied to contrast-enhanced multidetector computed tomography images. A retrospective cohort study of 62 subjects free of cardiovascular disease (55% females, age = 49 ± 11 years) conducted from 2008 to 2011 formed the study group. Intrathoracic fat volume was defined as all fat voxels measuring -50 to -250 Hounsfield Unit within the intrathoracic cavity from the level of the pulmonary artery bifurcation to the heart apex. The intrathoracic fat was separated into epicardial and extrapericardial fat by tracing the pericardium. The measurements were obtained by 2 readers and compared for interrater reproducibility. The fat volume measurements for the study group were 141 ± 72 cm3 for intrathoracic fat, 58 ± 27 cm3 for epicardial fat, and 84 ± 50 cm3 for extrapericardial fat. There was no statistically significant difference in intrathoracic fat volume measurements between the 2 readers, with correlation coefficients of 0.88 (P = .55) for intrathoracic fat volume and -0.12 (P = .33) for epicardial fat volume. Voxel-based measurement of intrathoracic fat, including the separation into epicardial and extrapericardial fat, is feasible and highly reproducible from multidetector computed tomography scans.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional reconstruction of New Zealand rabbit antebrachium by multidetector computed tomography

The aim of this study was to reveal biometric peculiarities of New Zealand white rabbit antebrachium (radius and ulna) by means of three-dimensional (3D) reconstruction of multidetector computed tomography (MDCT) images. Under general anesthesia, the antebrachiums of a total of sixteen rabbits of both sexes were scanned with a general diagnostic MDCT. Biometric measurements of the reconstructed...

متن کامل

Evaluation of body fat content and osteoarthritis in cats using computed tomography – a novel approach using whole-body imaging

Introduction Development of whole-body multidetector computed tomography (MDCT) methods have the potential to allow investigations into relations between feline osteoarthritis (OA) and obesity. In one MDCT examination all joints in an animal and the total body fat content can be evaluated. However, studies investigating the correlation between presence of joint lesions detected by MDCT and macr...

متن کامل

Evaluation of Left Atrial Volumes Using Multidetector Computed Tomography: Comparison with Echocardiography

OBJECTIVE To prospectively assess the relationship between the two different measurement methods for the evaluation of left atrial (LA) volume using cardiac multidetector computed tomography (MDCT) and to compare the results between cardiac MDCT and echocardiography. MATERIALS AND METHODS Thirty-five patients (20 men, 15 women; mean age, 60 years) underwent cardiac MDCT angiography for corona...

متن کامل

Diagnostic accuracy of multidetector computed tomography coronary angiography in patients with dilated cardiomyopathy.

OBJECTIVES The purpose of this work was to assess the safety, feasibility, and diagnostic accuracy of multidetector computed tomography (MDCT) in dilated cardiomyopathy (DCM) of unknown etiology. BACKGROUND Multidetector computed tomography is an appropriate noninvasive tool for coronary artery disease (CAD) detection, particularly in patients with low probability of the disease, such as pati...

متن کامل

Multidetector-row computed tomography of thoracic aortic anomalies in dogs and cats: Patent ductus arteriosus and vascular rings

BACKGROUND Diagnosis of extracardiac intrathoracic vascular anomalies is of clinical importance, but remains challenging. Traditional imaging modalities, such as radiography, echocardiography, and angiography, are inherently limited by the difficulties of a 2-dimensional approach to a 3-dimensional object. We postulated that accurate characterization of malformations of the aorta would benefit ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Tomography : a journal for imaging research

دوره 3 1  شماره 

صفحات  -

تاریخ انتشار 2017