Evaluation of the Diagnostic Performance of Fibrin Monomer in Disseminated Intravascular Coagulation
نویسندگان
چکیده
BACKGROUND Fibrin-related markers (FRM) such as fibrin monomer (FM) and D-dimer (DD) are considered useful biological markers for the diagnosis of disseminated intravascular coagulation (DIC). However, no studies on the diagnostic performance of different FRMs have been published in Korea. The aim of this study was to evaluate the diagnostic performance of FM for DIC in comparison with DD. METHODS The reference limit of FM was determined based on plasma sample data obtained from 210 control individuals. To evaluate diagnostic performance, FM data from the plasma samples of 139 patients with DIC-associated diseases were obtained for DIC scoring. FM was measured by immunoturbidimetry using STA-LIATEST FM (Diagnostica Stago, France). Patients were classified according to the DIC score as non-DIC, non-overt DIC, or overt DIC. ROC curve analyses were performed. RESULTS The reference limit in the control individuals was determined to be 7.80 µg/mL. Patients with DIC-associated diseases were categorized as non-DIC (N=43), non-overt DIC (N=80), and overt DIC (N=16). ROC curve analyses showed that the diagnostic performance of FM was comparable to DD in both non-overt DIC and overt DIC (P=0.596 and 0.553, respectively). In addition, FM had higher sensitivity, specificity, positive predictive value, and negative predictive value than DD for differentiating overt DIC from non-DIC. CONCLUSIONS This study demonstrated that the diagnostic performance of FM for DIC was comparable to DD. FM might be more sensitive and more specific than DD in the diagnosis of overt DIC, but not non-overt DIC.
منابع مشابه
The Effect of Preanalytical, Analytical, and Postanalytical Variables on D-dimer Measurement
D-dimer is a soluble fibrin degradation product deriving from the plasmin-mediated degradation of cross-linked fibrin. D-dimer can hence be considered a biomarker of activation of coagulation and fibrinolysis, and it is routinely used for ruling out venous thromboembolism (VTE). D-dimer is increasingly used to assess the risk of VTE recurrence and to help define the uoptimal duration of anticoa...
متن کاملPlasma Fibrinogen and D-dimer in Children With Sepsis: A Single-center Experience
Background & Objectives: In sepsis, enhanced fibrin formation, impaired fibrin degradation, and intravascular fibrin deposition lead to a prothrombotic state. The current study aimed at measuring various coagulation parameters to predict an early marker for disseminated intravascular coagulation (DIC). Methods: The current prospective s...
متن کاملSevere bleeding tendency caused by a rare complication of excessive fibrinolysis with disseminated intravascular coagulation in a 51-year-old Japanese man with prostate cancer: a case report
UNLABELLED INTRODUCTION Disseminated intravascular coagulation causes thrombotic tendency leading to multiple organ failure and occurs in a wide variety of diseases including malignancy. Disseminated intravascular coagulation is a latent complication in people with prostate cancer. CASE PRESENTATION A 51-year-old Japanese man with advanced castration-resistant prostate cancer was admitted ...
متن کاملDisseminated Intravascular Coagulation in a Case of Brucellosis Misdiagnosed as Thrombotic Thrombocytopenia Purpura
متن کامل
Analysis of elevated fibrin(ogen) degradation product levels in patients with liver disease.
Plasma and serum from patients with liver disease and elevated fibrin(ogen) degradation product (FDP) levels as measured by latex agglutination were analyzed by immunoblotting to characterize the FDP in these patients. An antihuman fibrinogen antibody was used that recognizes fibrinogen, fibrin monomer, soluble high molecular weight fibrinogen and fibrin polymers, as well as high molecular weig...
متن کامل