A novel paclitaxel-eluting stent with an ultrathin abluminal biodegradable polymer 9-month outcomes with the JACTAX HD stent.

نویسندگان

  • Eberhard Grube
  • Joachim Schofer
  • Karl E Hauptmann
  • Georg Nickenig
  • Nicholas Curzen
  • Dominic J Allocco
  • Keith D Dawkins
چکیده

OBJECTIVES The JACTAX HD trial ("JACTAX" Trial Drug Eluting Stent Trial) evaluated the safety and clinical performance of a novel JACTAX HD (Boston Scientific Corporation, Natick, Massachusetts) paclitaxel-eluting stent (PES) in de novo coronary lesions. BACKGROUND The JACTAX HD (Boston Scientific) stent consists of a pre-crimped bare-metal Liberté (Boston Scientific) stent coated on its abluminal aspect with an ultrathin (<1 microm) 1/1 mixture of biodegradable polylactide polymer and paclitaxel applied as discrete microdots (nominal totals of 9.2 microg each of polymer and paclitaxel per 16-mm stent). METHODS In this prospective, single-arm, multicenter, first-human-use study (n = 103), the primary end point of 9-month major adverse cardiac events (MACE) (cardiac death, myocardial infarction, ischemia-related target vessel revascularization) was compared with an objective performance criterion (OPC) of 17% (11% MACE based on TAXUS ATLAS [TAXUS Liberté-SR Stent for the Treatment of de Novo Coronary Artery Lesions] trial results plus a pre-specified noninferiority margin of 6%). RESULTS The composite primary end point occurred in 7.8% of JACTAX HD patients with an upper 1-sided 95% confidence limit of 13.6%, thus meeting the pre-specified criteria for noninferiority. There was no death, Q-wave myocardial infarction, or stent thrombosis through 9 months. In-stent late loss was 0.33 +/- 0.45 mm, with an in-stent binary restenosis of 5.2% and net volume obstruction by intravascular ultrasound of 11.4 +/- 11.2%. CONCLUSIONS The JACTAX HD stent with an abluminal biodegradable polymer showed 9-month MACE, in-stent late loss, restenosis, and net volume obstruction comparable to that observed with the TAXUS Liberté (Boston Scientific) stent coated with a conformal durable polymer. Further studies are underway to better evaluate the potential of this new PES design, which might allow for more rapid endothelialization and improved vessel healing. ("JACTAX" Trial Drug Eluting Stent Trial; NCT00754728).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Strut coverage and vessel wall response to a new-generation paclitaxel-eluting stent with an ultrathin biodegradable abluminal polymer: Optical Coherence Tomography Drug-Eluting Stent Investigation (OCTDESI).

BACKGROUND Polymer-coated drug-eluting stents are effective in preventing restenosis but have been associated with delayed healing and incomplete strut coverage. It is unknown whether paclitaxel-eluting stents (PES) with minimal biodegradable abluminal coating enhances strut coverage while preventing neointimal hyperplasia. Using optical coherence tomography (OCT) as a primary imaging modality,...

متن کامل

Randomized clinical trial comparing abluminal biodegradable polymer sirolimus-eluting stents with durable polymer sirolimus-eluting stents

BACKGROUND The biodegradable polymer drug-eluting stents (DES) were developed to improve vascular healing. However, further data and longer-term follow-up are needed to confirm safety and efficacy of these stents. This randomized clinical trial aimed to compare safety and efficacy of 2 sirolimus-eluting stents (SES): Cordimax-a novel abluminal biodegradable polymer SES and Cypher Select-a durab...

متن کامل

A randomised comparison of a novel abluminal groove-filled biodegradable polymer sirolimus-eluting stent with a durable polymer everolimus-eluting stent: clinical and angiographic follow-up of the TARGET I trial.

AIMS The study sought to evaluate the safety and efficacy of FIREHAWK, a novel abluminal groove-filled biodegradable polymer sirolimus-eluting stent (SES) for treating patients with single de novo coronary lesions compared with the durable polymer everolimus-eluting stent (EES) XIENCE V. METHODS AND RESULTS A total of 458 patients with single de novo native coronary lesions ≤24 mm in length a...

متن کامل

The Ultimaster Biodegradable-Polymer Sirolimus-Eluting Stent: An Updated Review of Clinical Evidence

The Ultimaster coronary stent system (Terumo Corporation, Tokyo, Japan) represents a new iteration in drug-eluting stent (DES) technology that has recently received the Conformité Européenne (CE) mark approval for clinical use. The Ultimaster is a thin-strut, cobalt chromium, biodegradable-polymer, sirolimus-eluting coronary stent. The high elasticity of the biodegradable-polymer (PDLLA-PCL) an...

متن کامل

First report of a novel abluminal groove filled biodegradable polymer rapamycin-eluting stent in de novo coronary artery disease: results of the first in man FIREHAWK trial.

BACKGROUND Durable polymers used for first-generation drug-eluting stents (DES) potentially contribute to persistent inflammation and late DES thrombosis. We report the first in human experience with the rapamycin-eluting biodegradable polymer coated cobalt-chromium FIREHAWK stent with abluminal groove. METHODS A total of 21 patients with stable or unstable angina, or prior myocardial infarct...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JACC. Cardiovascular interventions

دوره 3 4  شماره 

صفحات  -

تاریخ انتشار 2010